User Manual

G3S-800-140-031 Installation & Service Manual
Copyright Powerwave Technologies, Inc., September 2001. All rights reserved
044-05095 Rev. A 5-4 September 2001
5-5.1.4 Spurious Test
8. With the power amplifier set at 140 watts power output, use the spectrum analyzer and
check the frequency band from 851 MHz to 869 MHz for spurious signals. Spurious signals
should be -60 dBc maximum. Record test data in table 5-3.
5-5.1.5 Input Return Loss Test
9. Reset and turn on amplifier module. Read and record the S
11
return loss measurement on
network analyzer. Input return loss should be –16 dB maximum. Record test data in table
5-3.