Warranty

Page 14 — English
WARNING:
When servicing, use only identical replacement parts.
Use of any other parts can create a hazard or cause
product damage.
Only the parts shown on the parts list are intended to be
repaired or replaced by the customer. All other parts should
be replaced at an authorized service center.
GENERAL MAINTENANCE
Keep the generator in a clean and dry environment where it
is not exposed to dust, dirt, moisture, or corrosive vapors.
Do not allow the cooling air slots in the generator to become
clogged with foreign material such as leaves, etc.
Do not use a garden hose to clean the generator. Water en-
tering the fuel system or other internal parts of the unit can
cause problems that will decrease the life of the generator.
To clean the unit:
Use a soft bristle brush and/or vacuum cleaner to loosen
and remove dirt and debris.
Clean air vents with low pressure air that does not exceed
25 psi.
Wipe the exterior surfaces of the generator with a damp
cloth.
CHECKING/REPLACING AIR FILTER
See Figure 8.
A dirty air filter will cause starting difficulty, loss of perfor-
mance, and shorten the life span of the engine. Check the
air filter monthly. For best performance, replace the air filter
at least once a year. See the Replacement Parts List for
available sizes and part numbers of these items and call
customer service at 1-877-617-3501 to order.
Remove air filter knobs and air filter cover.
Remove the air filter.
Replace with a new air filter.
Replace the air filter cover and knobs to secure.
NOTE: Do not run the generator without the air filter. Rapid
engine wear will result.
CHANGING ENGINE LUBRICANT
See Figure 9.
Remove the oil cap/dipstick.
Place a container underneath the oil drain plug to collect
used lubricant as it drains.
Unscrew the oil drain plug and remove.
Allow lubricant to drain completely.
NOTE: Drain the lubricant while the engine is still warm
but not hot. Warm lubricant will drain quickly and more
completely.
WARNING:
Do not change engine lubricant while it is hot. Accidental
contact with hot engine lubricant could result in serious
burns.
Reinstall the oil drain plug and tighten securely.
Refill with lubricant following the instructions in the
Checking/Adding Lubricant section. For amount of
lubricant needed to refill, see Product Specifications
earlier in this manual or the accompanying engine manual,
if applicable.
Reinstall the oil cap/dipstick.
NOTE: Used lubricant should be disposed of at an approved
disposal site. See your local oil retailer for more information.
SPARK PLUG MAINTENANCE
See Figure 10.
The spark plug must be properly gapped and free of deposits
in order to ensure proper engine operation. To check:
Remove the spark plug cap.
Clean any dirt from around base of spark plug.
Remove spark plug using wrench (not included).
Inspect spark plug for damage, and clean with a wire brush
before reinstalling. If insulator is cracked or chipped, spark
plug should be replaced. For replacement spark plug, see
Production Specifications earlier in this manual or the
accompaning engine manual, if applicable.
MAINTENANCE
OPERATION
Using the frame, get a firm grasp of the unit. Lift the unit
into a safe and comfortable carrying position.
NOTE: This tool is heavy and requires two people to lift.
To avoid back injury, keep your knees bent and lift with
your legs, not your back, and get help when needed.
HIGH ALTITUDE OPERATION
Specific modifications are needed for high-altitude operation.
Please contact your authorized service center for important
information regarding these modifications. Operating this
engine without the proper altitude modification may increase
the engine’s emissions and decrease fuel economy and
performance.