Operation Manual
POWE10090 EN
Copyright © 2018 VARO P a g e | 8 www.varo.com
▪ To prevent the oil from running out in an uncontrolled manner, hold a small metal chute
under the opening and collect the oil in a vessel until it has fully drained out of the
machine.
Important: The waste oil must be disposed of in the appropriate
collection point for waste oil.
▪ Add new oil (approx. 25 ml) through the oil filler opening until the oil level reaches the
required level. Tighten the hexagonal screw again.
▪ Re-check the oil level after a short period of operation.
10 MAINTENANCE
Check every day the tightening of screws and nuts. Except the procedures described in this
manual, this tool needs no specific maintenance. The repair of the tool's inner components is
of the competence of specialists. The cleaning of plastic parts is done with a soft damp cloth
and a bit of mild soap. Never submerge the tool and do not use detergents, alcohol, spirit,
etc...For an in-depth cleaning, please consult the after-sales department.
WARNING: For maintenance and cleaning, always remove the plug from
the electric power supply. Never use water or other liquids to clean
electric parts.
11 TECHNICAL DATA
Rated voltage
230 V
Rated frequency
50 Hz
Rated power
1500 W
Rotation speed
1400 min
-1
Cable length
5 m
Chuck type
HEX
Impact rate
1400 strks/min
Carbon brush motor
Yes
Impact force (Joule)
40J
Soft grip
Yes
Full metal body
Yes
12 NOISE
Noise emission values measured according to relevant standard. (K=3)
Acoustic pressure level LpA
82dB(A)
Acoustic power level LwA
104 dB(A)
ATTENTION! Wear hearing protection when sound pressure is over 85
dB(A).
aw (Vibration):
16.4 m/s²
K = 1.5 m/s²