• Do not use the inverter in temperatures over 104°F or under 32°F. • Failure to follow these safety guidelines could result in personal injury and/or the damage to the unit. It may also be void of the warranty. • Follow the instruction from the manufacturer of your vehicle battery and AC/110V appliance before connecting the inverter to a battery. Please pay more attention to the cautionary marking on your vehicle battery. PRODUCT INTRODUCTION Thank you for purchasing this POWERDRIVE™ inverter.
1 2 3 4 PD750 5 6 7 10 9 8
THE SELF PROTECTION OF YOUR INVERTER Possible cause Remove all appliances and turn off the unit by the ON/OFF switch. Recharge the battery. Remarks Type If the output power exceeds the rated output power 10 to 15%. Although the inverter has protection against over load, it may still damage the inverter if the input voltage exceeds 16V. Solution Current overload Input voltage lower than 10.5V. Remove all appliances and turn off the unit by the ON/OFF switch.
BATTERY OPERATING TIME Operating time will vary depending on the charge level of the battery, its capacity and the power level drawn by the particular AC load. With a typical vehicle battery load, an operating time of 1 hour or more can be expected. When using a vehicle battery as a power source, it is strongly recommended to start the vehicle every hour to recharge the battery before its capacity drops too low.
USB Power Output DC output voltage 5V DC, 2 ports shared 2.4 Amps output DC Power Specifications DC input voltage range 11V to 15V DC ≤ 0.6A Battery drain with no AC load Low battery shutdown point (nominal) 10.5±0.3V DC High battery shutdown point (nominal) Fuse 15.5±0.5V DC 35A x3 blade fuse Efficiency (maximum) 85% Physical Specifications Ambient operating temperature range 32°F to 104°F TROUBLESHOOTING Problem Cause Solution No power, no indicator Battery is defective. Replace battery.
Problem Cause Solution Inverter runs small loads but not large loads. Low voltage battery. Charge the battery. Water entered. Water entered the unit. Disconnect the inverter and wipe immediately with a dry cloth, or permanent damage can occur from the liquid. Measured inverter output is too low Standard “average-reading” AC voltmeter used to measure output voltage, resulting in an apparent reading 5V to 15V too low.