Datasheet

Printed at 12-06-2015 03:06
- 1 -
IXARC Rotary Encoder
OCD-S5A1G-0016-CA30-2AW
Interface
Interface SSI with Preset + Incremental RS422
Manual Functions Preset + complement via cable or connector
Interface Cycle Time > 25 µs
Outputs
Output Driver SSI (RS422) / Incr. (RS422)
Output Incremental A, /A, B, /B, Z, /Z
Quadrature Phasing 90° ± 4.5° electrical
Max. Frequency Response 2 MHz
Electrical Data
Supply Voltage 4.5 – 30 VDC (On power supplies comply with EN 50178)
Power Consumption ≤ 1.5 W
Start-Up Time < 250 ms
Clock Input RS 422, via Optocoupler
Clock Frequency 100 kHz – 2 MHz
Reverse Polarity Protection Yes
Short Circuit Protection Yes
EMC: Emitted Interference DIN EN 61000-6-4
EMC: Noise Immunity DIN EN 61000-6-2
MTTF 16.2 years @ 40 °C
Sensor

Summary of content (4 pages)