Data Sheet
Data Sheet
Printed at 27-09-2017 13:09
- 1 / 5 -
TILTIX Inclinometer
ADS-010-2-AV00-HE2-AW
General Specifications
Application 2-Axes Position Monitoring and Leveling
Measurement Range ± 10°
Absolute Accuracy 0.50°
Resolution 0.01°
Electrical Specifications
Supply Voltage 10 – 30 VDC
Power Consumption (no load) ≤ 0.7 W
EMC: Emitted Interference DIN EN 61000-6-4
EMC: Noise Immunity DIN EN 61000-6-2
Reverse Polarity Protection Yes
Short Circuit Protection Yes
Environmental Specifications
Operating Temperature -30 °C fixed (-22 °F), -5 °C flexible (+23 °F) - +70
°C (+158 °F)
Storage Temperature -40 °C (-40 °F) – +85 °C (+185 °F)
Temperature Gradient 0.004°/ K
Protection Class IP66/IP67
Shock Resistance ≤ 100 g (half sine 6 ms, EN 60068-2-27)
Vibration Resistance 1.5 mm (10 Hz – 58 Hz) & ≤ 20 g (58 Hz to 2000
Hz)