MSDS

4
or vapors of the component Dimethyl Ketone may present a hazard of
flammability. If involved in a fire, the product may produce irritating vapors
and toxic gases (e.g. carbon monoxide, carbon dioxide). The following are
recommended for extinguishing fires involving this product: Water Spray:
YES (for cooling only); Foam: YES; Halon: YES; Carbon Dioxide: YES; Dry
Chemical: YES; Other: Any “B” Class.
Special Fire Fighting Procedures: Fire fighter should wear self-contained breathing apparatus and full
protective clothing. Use water spray to cool nearby containers and
structures exposed to fire. Move canisters from fire area if it can be done
without risk to personnel. If possible, prevent runoff water from entering
storm drains, bodies of water, or other environmentally sensitive areas.
Rinse contaminated equipment thoroughly with soapy water before returning
such equipment to service.
-------------------------------------------------------------------------------------------------------------------------------------------------------------------
SECTION 6. ACCIDENTAL RELEASE MEASURES
If material is released or spilled: Ventilate area, especially low places where heavy vapors might collect.
Remove all possible sources of ignition. Avoid prolonged breathing of vapors.
Use self-contained breathing apparatus for large spills/releases. Use
appropriate personal protection equipment during clean up. Product is highly
volatile, rapidly evaporates.
Absorb spilled liquid with activated carbon, polypads or other suitable absorbent
materials. If necessary, rinse contaminated area and equipment with soapy
water, followed by a triple-rinse with water. Decontaminate the area
thoroughly. Place all spill residue in a suitable container.
Waste disposal: Comply with all Federal, State and local Regulations, or appropriate
standards of Canada, EU Member States, or those of other countries.
-------------------------------------------------------------------------------------------------------------------------------------------------------------------
SECTION 7. HANDLING AND STORAGE
Respiratory Protection: Under normal manufacturing conditions, no respiratory protection is required
when using this product. Self-contained breathing apparatus (SCBA) is
required if a large release occurs.
Ventilation: Use adequate ventilation in volume and pattern to keep exposure below
recommended levels. Normal ventilation for standard manufacturing
procedures is generally adequate. Local exhaust should be used when
large amounts are released. Mechanical ventilation should be used in low
places. General mechanical: ventilation should comply with OSHA
1910.94. Should not be mixed with air for leak testing or used with air for any
other purpose above atmospheric pressure.
Hand Protection: Wear chemically-resistant gloves when using this product. Butyl rubber
gloves, Teflon™, 4h™, Barricade™, Chemrel™, Responder™ are
recommended of estimated resistance to break-through longer than four (4)
hours.
Eye Protection: Safety glasses, goggles with splash guards or face/side shields.
Body Protection/Other Protective Equipment: Use body protection appropriate to the task. Avoid breathing vapors
and liquid contact with skin or eyes.
Additional: Store in cool, dry area away from sources of ignition and
incompatible materials. When storing large quantities, store in
building designed and protected against fire.
DO NOT STORE IN DIRECT SUNLIGHT OR ABOVE 120
o
F.
-------------------------------------------------------------------------------------------------------------------------------------------------------------------