506 Twin Oaks Drive Johnson City, TN 37601 WHIRLPOOL BATH Installation Instructions
TABLE OF CONTENTS Important Safety Information .........................................................................................................................3 Important Installation Information .................................................................................................................4 Testing Prior to Taking Indoors .......................................................................................................................
ATTENTION INSTALLER: SAVE THESE INSTRUCTIONS GIVE THIS MANUAL TO THE BATH OWNER. CONTAINS IMPORTANT SAFETY INSTRUCTIONS PERTAINING TO RISK OF FIRE, ELECTRIC SHOCK, OR INJURY TO PERSONS READ AND FOLLOW ALL INSTRUCTIONS WARNING: Risk of accidental injury or drowning. Do not use this hydrotherapy bath unless all suction guards or intake covers for suction pumps are installed and in good condition to prevent body and hair entrapment. WARNING: Risk of accidental injury or drowning.
IMPORTANT!: Signature Baths are intended for indoor use only with installation in accordance with all instructions in this book. IMPORTANT!:To reduce the risk of personal injury and discoloration of the acrylic surface, water temperatures from the inlet should not exceed 140º F. Use supply lines suitable for 167º F, including the temperature rating of supply conductors to be used. IMPORTANT!: Do not drop or insert any object into any opening.
8. 9. Troubleshooting Leaks: • If there is a leaks at plumbing unions are not resolved by tightening, loosen the unions and inspect the seals to confirm they are properly seated. • If water surges or does not flow through the jets when turned the pump is turned on, make sure the water level is above the jets. The pump will not operate properly without enough water in the bath. If there is adequate water in the bath, air may be trapped in the pump.
ELECTRICAL CONNECTIONS DANGER: Risk of severe injury from electric shock or death by electrocution. This bath must be must be connected directly to a dedicated 120V 15 amp supply circuit that is protected by a Ground Fault Circuit Interrupter (GFCI) installed by a qualified, licensed electrician in accordance with national electric and local codes and the GFCI manufacturer’s instructions. The GFCI should be tested regularly. To test the GFCI, push the “TEST” button.
FRAMING THE BATH For proper drainage and stability, your Signature bath must be level and the full bottom of the full bath be seated firmly on the sub-floor. If the sub-floor requires leveling, measurements must be adjusted to include clearance for mortar between the floor and the bottom of the bath. The rim of the bath will not support weight. Three Wall Alcove Installation: The interior of the alcove must be the same size as the exterior dimension of the bath.
PLUMBING CONNECTIONS Important: Risk of damage to bath bottom and sub-floor. It is the installer’s responsibility to ensure watertight seal on installed connections. Important: Proper installation of the hardware and compliance with codes is the responsibility of the installer. Signature Bath does not warrant connections of water supply fittings and lines, fill systems, or drain/overflow systems and is not responsible for damage to the bath that occurs during installation.
OPERATING INSTRUCTIONS DANGER: Risk of accidental injury or drowning. Do not permit children to use this bath unless they are closely supervised by a responsible adult at all times. Never leave a full bath unattended. WARNING: Risk of severe injury by electric shock. Do not permit electric appliances (such as a hair dryer, lamp, telephone, radio or television) within 5 feet of this bath. WARNING: Risk of accidental injury or drowning.
• • • • • • • • • • • CLEANING YOUR SIGNATURE BATH After each use, clear hair and lint from the suction cover and rinse your bath well. Clean frequently with a soft cloth and mild liquid detergent mixed with warm water. Rinse well after cleaning. Once each month, fill your bath with hot water above the jets and add a sanitizer safe for acrylic surfaces following the instructions on the label. Turn the pump on, run for 10 minutes and drain.
SIGNATURE BATH MANUFACTURER’S LIMITED WARRANTY for Whirlpool Baths Warranty Coverage Throughout this document, Signature Bath shall be referred to as the “MANUFACTURER”. The following expressed limited lifetime warranty is given to the original consumer of a Luxury or Luxury Plus Series Signature Bath purchased for personal or single family residential use. Any commercial applications are excluded from all warranties.
506 Twin Oaks Drive Johnson City, TN 37601