Datasheet

PNOZmulti 2 products
Fieldbus modules
PNOZ m ES CC-Link
Pilz GmbH & Co. KG, Felix-Wankel-Straße 2, 73760 Ostfildern, Germany
Telephone: +49 711 3409-0, Telefax: +49 711 3409-133, E-Mail: info@pilz.com
2015-11
896
LED status
The LED status of PNOZmulti 2 can be read out via the following High Byte.
High Byte Low Byte
Bit no 7 6 5 4 3 2 1 0 7 6 5 4 3 2 1 0
RWr (l+2) LED Byte Output data o120 - o127
} Bit 0 = 1: LED OFAULT is lit or flashes
} Bit 1 = 1: LED IFAULT is lit or flashes
} Bit 2 = 1: LED FAULT is lit or flashes
} Bit 3 = 1: LED DIAG is lit or flashes
} Bit 4 = 1: LED RUN FS is lit
} Bit 5-7: Reserved
Access to table segments
The data in the tables can be requested via the following addresses.
Input data
The Master requests a table segment:
High Byte Low Byte
RWw (l+3) Segment number Table number
Output data
PNOZmulti 2 answers as follows:
High Byte Low Byte
RWr (l+3) Segment number Table number
RWr(l+4) Segment Byte 1 Segment Byte 0
RWr(l+5) Segment Byte 3 Segment Byte 2
RWr(l+6) Segment Byte 5 Segment Byte 4
RWr(l+7) Segment Byte 7 Segment Byte 6
RWr(l+8) Segment Byte 9 Segment Byte 8
RWr(l+9) Segment Byte 11 Segment Byte 10
RWr(l+A) Reserved Segment Byte 12
RWr(l+B) Reserved Reserved