Datasheet

Relays for functional safety
Safety relays PNOZsigma
PNOZ s50
Pilz GmbH & Co. KG, Felix-Wankel-Straße 2, 73760 Ostfildern, Germany
Telephone: +49 711 3409-0, Telefax: +49 711 3409-133, E-Mail: info@pilz.com
2016-09
930
Overview Display Description
Counter 1 or
Counter 2
Switch to menu to
set the counter for
the number of oper-
ations for power cir-
cuits O1+/O1- or
O2+/O2-
Counter 1
Set:
Cancel Store
Counter 2
Counter 1 – Event counter 1 - Configure
number of operations for load at power cir-
cuit O1+/O1-
Counter 2 – Event counter 2 - Configure
number of operations for load at power cir-
cuit O2+/O2-
######## – Old counter status
Set: – Enter new counter status, e.g.
when a used load is applied
Value range: 0 … 99999999
Store – Confirm entry
Cancel – Exit menu without confirming the
entry
Change password
PIN
Change password
PIN
Old _ _ _ _ _ _
New _ _ _ _ _ _
Cancel Store
Old – Enter the old password
New – Enter the new password
Cancel – Exit menu without confirming the
entry
Store – Adopt new password
Denied Wrong PIN
Error message
Denied
Wrong PIN
You entered an incorrect password
Restart after changing configuration
Adopt changes
and Reboot
Restart and adopt
configuration
Adopt changes
and Reboot
Are you sure?
No Yes
No – Do not restart
Yes – Restart
Restart device
Restart the device if you have changed the configuration. The changed configuration is ad-
opted during a restart.
There are two options for restarting the device once the configuration is complete.
Option one:
1. Switch off the device's supply voltage (terminals A1 and A2).
2. Switch the device's supply voltage back on.
The configuration is adopted.