Datasheet

Relays for functional safety
Safety relays PNOZsigma
PNOZ s30
Pilz GmbH & Co. KG, Felix-Wankel-Straße 2, 73760 Ostfildern, Germany
Telephone: +49 711 3409-0, Telefax: +49 711 3409-133, E-Mail: info@pilz.com
2016-09
862
Information
Level Menu designation Description Display/Settings
1 System Time Time that the device is switched
on
xxx.xxx h
xx min xx s
1 Max. Speed
Track AB
Max. measured linear/rotational
speed at tracks A and B
The value can be reset to 0
0 … 4.29 MHz
or the corresponding value in the set
unit
Reset:
Reset:
- Yes ?
-
No
1 Max. Speed
Track Z
Max. measured linear/rotational
speed at track Z
The value can be reset to 0
0 … 4.29 MHz
or the corresponding value in the set
unit
Reset:
Reset:
- Yes?
- No?
1 Relay (Ctrl, 1, 2)
Cycles
Information:
Total number of relay operations
Relay Ctrl (Root relay, common
2nd shutdown route)
Relay 1 (Relay output 1: 11-12,
13-14)
Relay 2 (Relay output 2: 21-22,
23-24)
0 ... 6,000,000 x, > 6,000,000 x
1 CRC of Configura-
tion
Check sum of configuration para-
meters
0 ... 65535