Datasheet

Relays for functional safety
Safety relays PNOZ X
PNOZ X11P
Pilz GmbH & Co. KG, Felix-Wankel-Straße 2, 73760 Ostfildern, Germany
Telephone: +49 711 3409-0, Telefax: +49 711 3409-133, E-Mail: info@pilz.com
2016-09
269
Times 787080 787083 787086
Switch-on delay
With automatic start
typ. 450 ms 450 ms 450 ms
With automatic start
max. 680 ms 680 ms 680 ms
With automatic start
after power on typ. 450 ms 450 ms 450 ms
With automatic start
after power on max. 630 ms 630 ms 630 ms
With manual start typ. 450 ms 450 ms 450 ms
With manual start max. 680 ms 680 ms 680 ms
With monitored start
typ. 390 ms 390 ms 390 ms
With monitored start
max. 550 ms 550 ms 550 ms
Delay-on de-energisation
With E-STOP typ. 15 ms 15 ms 15 ms
With E-STOP max. 30 ms 30 ms 30 ms
With power failure typ. 40 ms 40 ms 40 ms
With power failure max. 60 ms 60 ms 60 ms
Recovery time at max.
switching frequency 1/s
After E-STOP 50 ms 50 ms 50 ms
After power failure 100 ms 100 ms 100 ms
Min. start pulse duration
with a monitored start 30 ms 30 ms 30 ms
Supply interruption before
de-energisation 20 ms 20 ms 20 ms
Simultaneity, channel 1
and 2 max.
Environmental data 787080 787083 787086
Climatic suitability EN 60068-2-78 EN 60068-2-78 EN 60068-2-78
Ambient temperature
Temperature range -10 - 55 °C -10 - 55 °C -10 - 55 °C
Storage temperature
Temperature range -40 - 85 °C -40 - 85 °C -40 - 85 °C
Climatic suitability
Humidity 93 % r. h. at 40 °C 93 % r. h. at 40 °C 93 % r. h. at 40 °C
Condensation during op-
eration Not permitted Not permitted Not permitted
EMC EN 60947-5-1, EN
61000-6-2, EN 61326-3-1
EN 60947-5-1, EN
61000-6-2, EN 61326-3-1
EN 60947-5-1, EN
61000-6-2, EN 61326-3-1