Datasheet

Relays for functional safety
Safety relays PNOZ X
PNOZ X7P
Pilz GmbH & Co. KG, Felix-Wankel-Straße 2, 73760 Ostfildern, Germany
Telephone: +49 711 3409-0, Telefax: +49 711 3409-133, E-Mail: info@pilz.com
2016-09
171
Times 777053 777056 777059
Switch-on delay
With automatic start
typ. 230 ms 230 ms 50 ms
With automatic start
max. 700 ms 700 ms 150 ms
With automatic start
after power on typ. 230 ms 230 ms 50 ms
With automatic start
after power on max. 700 ms 700 ms 150 ms
With manual start typ. 140 ms 140 ms 35 ms
With manual start max. 700 ms 700 ms 150 ms
Delay-on de-energisation
With E-STOP typ. 70 ms 70 ms 45 ms
With E-STOP max. 100 ms 100 ms 70 ms
With power failure typ. 70 ms 70 ms 45 ms
With power failure max. 100 ms 100 ms 70 ms
Recovery time at max.
switching frequency 1/s
After E-STOP 120 ms 120 ms 50 ms
After power failure 120 ms 120 ms 150 ms
Supply interruption before
de-energisation 20 ms 20 ms 20 ms
Environmental data 777053 777056 777059
Climatic suitability EN 60068-2-78 EN 60068-2-78 EN 60068-2-78
Ambient temperature
Temperature range -10 - 55 °C -10 - 55 °C -10 - 55 °C
Storage temperature
Temperature range -40 - 85 °C -40 - 85 °C -40 - 85 °C
Climatic suitability
Humidity 93 % r. h. at 40 °C 93 % r. h. at 40 °C 93 % r. h. at 40 °C
Condensation during op-
eration Not permitted Not permitted Not permitted
EMC EN 60947-5-1, EN
61000-6-2, EN 61326-3-1
EN 60947-5-1, EN
61000-6-2, EN 61326-3-1
EN 60947-5-1, EN
61000-6-2, EN 61326-3-1
Vibration
In accordance with the
standard EN 60068-2-6 EN 60068-2-6 EN 60068-2-6
Frequency 10 - 55 Hz 10 - 55 Hz 10 - 55 Hz
Amplitude 0,35 mm 0,35 mm 0,35 mm