Datasheet

Relays for functional safety
Safety relays PNOZsigma
PNOZ s50
Pilz GmbH & Co. KG, Felix-Wankel-Straße 2, 73760 Ostfildern, Germany
Telephone: +49 711 3409-0, Telefax: +49 711 3409-133, E-Mail: info@pilz.com
2016-09
910
Inputs
Fast shutdown
Activation via safe single-pole
outputs
Link Y12 – Y13
Link Y22 – Y23
PLC: Safety control system
Y10
Y11
Y12
Y13
O1
O2
Y20
Y21
Y22
Y23
O3
O4
PLC
PNOZ s50
Activation via safe dual-pole
outputs
Link Y10 – Y11
Link Y20 – Y21
PLC: Safety control system
Y10
Y11
Y12
Y13
O1+
O1-
Y20
Y21
Y22
Y23
O2+
O2-
PLC
PNOZ s50