Datasheet

Relays for functional safety
Safety relays PNOZ X
PNOZ X2.7P
Pilz GmbH & Co. KG, Felix-Wankel-Straße 2, 73760 Ostfildern, Germany
Telephone: +49 711 3409-0, Telefax: +49 711 3409-133, E-Mail: info@pilz.com
2016-09
72
Input circuit Single-channel Dual-channel
Light guards or safety switch, de-
tection of shorts across contacts
via ESPE
(only when U
B
= 24 VDC);
Order no. 777305, 787305)
Start circuit Single-channel Dual-channel
Monitored start
Feedback loop Automatic start Monitored start
Contacts from external contact-
ors
K5
K6
K5
L1
K6
S12
S34
S3
N
13 (23, 33)
14 (24 ,34)
Legend
} S1/S2: E-STOP/safety gate switch
} S3: Reset button
} : Switch operated
} : Gate open
} : Gate closed