Datasheet

Relays for functional safety
Safety relays PNOZ X
PZE 9P
Pilz GmbH & Co. KG, Felix-Wankel-Straße 2, 73760 Ostfildern, Germany
Telephone: +49 711 3409-0, Telefax: +49 711 3409-133, E-Mail: info@pilz.com
2016-09
487
Inputs 777140 787140
Max. overall cable resistance Rl-
max
Single-channel at UB DC 50 Ohm 50 Ohm
Single-channel at UB AC 80 Ohm 80 Ohm
Dual-channel without detection
of shorts across contacts at UB
DC 100 Ohm 100 Ohm
Dual-channel without detection
of shorts across contacts at UB
AC 160 Ohm 160 Ohm
Dual-channel with detection of
shorts across contacts at UB DC 5 Ohm 5 Ohm
Dual-channel with detection of
shorts across contacts at UB AC 10 Ohm 10 Ohm
Relay outputs 777140 787140
Number of output contacts
Safety contacts (N/O), instant-
aneous 8 8
Auxiliary contacts (N/C) 1 1
Max. short circuit current IK 1 kA 1 kA
Utilisation category
In accordance with the standard EN 60947-4-1 EN 60947-4-1
Utilisation category of safety con-
tacts
AC1 at 240 V 240 V
Min. current 0,01 A 0,01 A
Max. current 8 A 8 A
Max. power 2000 VA 2000 VA
DC1 at 24 V 24 V
Min. current 0,01 A 0,01 A
Max. current 8 A 8 A
Max. power 200 W 200 W
Utilisation category of auxiliary con-
tacts
AC1 at 240 V 240 V
Min. current 0,01 A 0,01 A
Max. current 2 A 2 A
Max. power 500 VA 500 VA
DC1 at 24 V 24 V
Min. current 0,01 A 0,01 A
Max. current 2 A 2 A
Max. power 50 W 50 W