Datasheet

Relays for functional safety
Safety relays PNOZsigma
PNOZ s30
Pilz GmbH & Co. KG, Felix-Wankel-Straße 2, 73760 Ostfildern, Germany
Telephone: +49 711 3409-0, Telefax: +49 711 3409-133, E-Mail: info@pilz.com
2016-09
883
Permitted output signals:
} Square output signals TTL, single ended
} Square output signals TTL, differential
} Square output signals HTL, single ended
} Square output signals HTL, differential
} Sin/Cos output signals 1Vss, reference voltage
} Sin/Cos output signals 1Vss, differential
Reference sensor
Permitted encoder types:
} Rotary non-safety-related encoders
} Linear non-safety-related encoders
} Inductive proximity switches
Permitted output signals:
} Square output signals HTL, single ended
} Square output signal 24 V, pnp
Safety-related architecture
Sensor
non-safe encoder
Actuator
SRP/CS
Actuator
SRP/CS
Sensor
PNOZ s30
Logic
+
Diagnostic
SRP/CS
Logic
Sensor
proximity switch
To calculate the safety function you will need the following data for the "sensor" subsystem
and "PNOZ s30" subsystem:
Sensor PNOZ s30 subsystem
Category MTTFd DC Operating mode PFH (1/h)
4 Manufacturer-
specific
90 % Monitoring
2 encoders
1,44E-09
In a worst case scenario, the sensor subsystem's characteristic value MTTFd is calculated
from the inferior (lower) value of the two sensors.