Datasheet

Relays for functional safety
Safety relays PNOZsigma
PNOZ s30
Pilz GmbH & Co. KG, Felix-Wankel-Straße 2, 73760 Ostfildern, Germany
Telephone: +49 711 3409-0, Telefax: +49 711 3409-133, E-Mail: info@pilz.com
2016-09
859
Level
Designation
on the display
Description Settings
2 Start mode
((Rel.1 ... Out 4) )
Default
Monitored /
Select start mode for each output
separately
Automatic: Automatic start
Monitored /: Monitored start with
rising edge at S34
Monitored \: Monitored start with
falling edge at S34
- Automatic
- Monitored /
-Monitored \
Advanced settings
Level Menu designation Description Settings
1 Positions Para-
meter
Settings for position monitoring
functions
2 Position (1 ... 4)
Window width
Default
1 pulse
Enter width of position window for
position monitoring functions 1 ...
4
1 ... 24,900,000 pulses
or the corresponding value in the selec-
ted unit
1 Direction Parameter Settings for direction monitoring
2 (Direct. Left max.
right, Direct. Right
max. left)
Default
0 pulse
Enter max. tolerated number of
pulses (or Edg, m, rot) in the
wrong direction.
1 ... 24,900,000 pulses
or the corresponding value in the selec-
ted unit
1 Mode
Select Input
Default
None
Setting for using the select inputs -All 16
-1 from 4
-None
1 Delay
Select Input
Default
tdl : 0 ms
Enter delay time of the select in-
puts Y10 – Y13
Info: The states of the select in-
puts are only adopted if they were
unchanged during the set time.
0 ... 30.0 s
1 Function Hysteresis