Datasheet

Relays for functional safety
Safety relays PNOZ X
PMUT X1P
Pilz GmbH & Co. KG, Felix-Wankel-Straße 2, 73760 Ostfildern, Germany
Telephone: +49 711 3409-0, Telefax: +49 711 3409-133, E-Mail: info@pilz.com
2016-09
500
PMUT X1P
Unit features
} Positive-guided relay outputs:
3 safety contacts (N/O), instantaneous
1 auxiliary contact (N/C), instantaneous
} 4 inputs for muting sensors
} 1 ESPE input for light grids (2-channel, contact or semiconductor outputs)
} 1 input for additional safety light grid (2-channel, contact outputs) or safety contacts
} Connection option for 2 muting lamps
} Connection options for:
Start button
Key switch
Feedback loop
} 5 semiconductor outputs
} Monitors muting lamps
} Muting mode: sequential or parallel
} LED display for:
Switch status channel 1/2
Muting sensors
Light grid
Simultaneity requirement
Muting lamp error
} Semiconductor outputs signal:
Switch state of the safety contacts
Muting active
One of the muting lamps defective
Both muting lamps defective
Light grid (ESPE) active
} Plug-in connection terminals (either spring-loaded terminal or screw terminal)