User Manual

PSEN ml b 1.1
Operating Manual PSEN ml b 1.1
1003884-EN-05
8
For your safety
WARNING!
Loss of safety function due to substituting an actuator from the interlocking
and guard locking system
Substituting an actuator for an inappropriate actuator may lead to serious in-
jury and death.
You should prevent the interlocking and guard locking system from
being manipulated with an inappropriate actuator.
Keep the substitute actuator in a safe place and protect it from unau-
thorised access.
If substitute actuators are used, these must be installed as described
under Installation [ 16]
If the original actuators are replaced with substitute actuators, the ori-
ginal actuators must be destroyed before disposal.
Unit features
} Safe guard locking for swing gates and sliding gates
} Safe interlocking (position monitoring)
} Transponder technology
} 2 safety outputs
} Monitoring of shorts between the safety outputs
} Guard locking element keeps the safety gate from being opened unintentionally
} Auxiliary release for opening the safety gate
} 1 signal output
} Suitable for left and right hinged safety gates
} Pilz coding type: Coded
} M12, 8-pin male connector
} LEDs:
Supply voltage/fault
Status of actuator
Status of guard locking
Input lights up yellow (without function)
} The bolt in the actuator can be rotated 90° in the actuator housing before the actuator is
installed. As a result, the actuator can be installed vertically or horizontally.