User Manual

PSEN cs6.1p
Operating Manual PSEN cs6.1p
1003422-EN-05 Draft1
6
INFORMATION
This gives advice on applications and provides information on special fea-
tures.
Safety
Intended use
The safety functions of the safety switch are:
} Safe shutdown of safety outputs when the actuator is removed beyond the assured re-
lease distance s
ar
or when the actuator is not detected
} Remain shut down safely after the actuator has been removed
The safety switch meets the requirements in accordance with:
} EN 60947-5-3 with the actuator PSEN cs6.1 : PDDB
} EN 62061: SIL CL 3
} EN ISO 13849-1: PL e (Cat. 4)
} ENISO14119: Coding level High, Type4
The safety switch may only be used with the corresponding actuator PSEN cs6.1.
The safety level PL e (Cat. 4 )/SIL CL 3 is only achieved if
} the safety outputs use 2-channel processing.
The following is deemed improper use in particular:
} Any component, technical or electrical modification to the product
} Use of the product outside the areas described in this manual
} Use of the product outside the technical details (see Technical details [ 32]).
NOTICE
EMC-compliant electrical installation
The product is designed for use in an industrial environment. The product
may cause interference if installed in other environments. If installed in other
environments, measures should be taken to comply with the applicable
standards and directives for the respective installation site with regard to in-
terference.