User Manual

PSEN cs1.1p
Operating Manual PSEN cs1.1p
21095-EN-08
18
Technical details
General
Approvals CE, EAC (Eurasian), FCC, IC, TÜV, cULus Listed
Sensor's mode of operation Transponder
Coding level in accordance with EN ISO 14119 Low
Design in accordance with EN ISO 14119 4
Classification in accordance with EN 60947-5-3 PDDB
Pilz coding type Coded
Electrical data
Supply voltage
Voltage 24 V
Kind DC
Voltage tolerance -20 %/+20 %
Output of external power supply (DC) 2 W
Max. inrush current at UB 0,12 A
Max. switching frequency 3 Hz
Max. cable capacitance at the safety outputs
No-load, PNOZ with relay contacts 40 nF
PNOZmulti, PNOZelog, PSS 70 nF
No-load current 50 mA
Inputs
Number 2
Voltage at inputs 24 V DC
Input current range 5 mA
Max. overall cable resistance Rlmax
Single-channel at UB DC 1000 Ohm
Semiconductor outputs
OSSD safety outputs 2
Signal outputs 1
Switching current per output 500 mA
Breaking capacity per output 12 W
Potential isolation from system voltage No
Short circuit-proof ja
Residual current at outputs 10 µA
Voltage drop at OSSDs 3,5 V
Lowest operating current 0 mA
Utilisation category in accordance with EN 60947-1 DC-12
Times
Test pulse duration, safety outputs 450 µs
Switch-on delay
after UB is applied 1 s
Inputs typ. 13 ms
Inputs max. 20 ms
Actuator typ. 45 ms
Actuator max. 100 ms