Datasheet

1 FBRNI 10-6
2 TS-URTK/SS
3 ATS-URTK/SS
4 D-URTK/SS
2770626
0321213
0321226
0321022
10987654321 11 12
1 2 314
1234 5678910 11 12
1 2 3 12 4
1 FB 10-GSK/S
2 GS-GSK/S
3 ATS-GSK
4 D-UGSK
0305174
0305116
0304227
0304023
Dimensions
[mm]
Dimensions
[mm]
Max. electrical data
Rated data
Rated voltage [V] 400 300 300 - 400 - - - 500 - - -
Nominal current / cross section [A] / [mm²] 26 / 4 20 / - 25 / - - 26 / 4 - - - 41 / 6 - - -
Rated cross section [mm²] 4--- 4--- 6---
Cross section range AWG 24 - 12 28-12 28-12 - 24 - 12 - - - 20 - 8 - - -
Connection capacity
1 conductor [mm²] 0.2 - 4 0.2 - 4 0.25 - 4 0.25 - 2.5 0.2 - 4 0.2 - 4 0.25 - 4 0.25 - 2.5 0.5 - 10 0.5 - 6 0.5 - 6 0.5 - 4
2 conductors (of the same type) [mm²] 0.2 - 1.5 0.2 - 1.5 0.25
2 stranded conductors with a TWIN ferrule [mm²] - - - 0.5 - 2.5 - - - 0.5 - 2.5 - - - 0.5 - 4
General data
Stripping length [mm] 7 7 11
Terminal point: thread / torque - / [Nm] M3 / 0.6 - 0.8 M3 / 0.6 - 0.8 M4 / 1.5 - 1.8
Disconnect slide: thread / torque - / [Nm] M2,6 / 0.5 - 0.6 M2,6 / 0.5 - 0.6 M2,6 / 0.5 - 0.6
Insulating material
Inflammability class according to UL 94 V0 V0 V2
Description
No. of
pos.
Color
Measurement/disconnect terminal block, for
mounting on NS32... or NS35...
gray
with test sockets gray
Slide terminal block, for mounting on NS32... or
NS35...
gray
Without slide gray
Cover, width 1 mm gray
Cover, width 2.2 mm gray
Fixed bridge, for cross connections on both sides of the
disconnect point, can be separated, with 10 screws
10 silver
Slide, for switchable connection along with FB 10-GSK/S or FB-
GSK
silver
Separating plate, for separation of neighboring
bridges in terminal center, width 0.8mm
gray
Separating disk, 0.8mm wide gray
Slide with a test socket, insulated, for the
UGSK/S terminal block, M3.5 thread
transparent
white
red
blue
yellow
green
violet
gray
black
Screwdriver
Lateral groove marking
420
PHOENIX CONTACT
Simple and clear testing in current
transformer secondary circuits can be
undertaken with the slide-type terminal
block UGSK/S for cross switching
Measurement equipment or protective
relays can be individually activated with
the aid of bridges and slides
For this purpose, the slides make contact
with the switching jumper depending on
the switching task
The URTK/SS allow the transformer test
circuits to be designed in a very compact
and clear way
Knife disconnect terminal block URTK/SS
Type Order no.
Open
Slide-type terminal block UGSK/S
Type Order no.
Slide-type terminal block UGSK/S
Test disconnect terminal block
URTK/SS
Terminal blocks
UK universal terminal blocks