Datasheet
For further information and full technical data, visit phoenixcontact.net/products
Technical data
Dimensions Width Length Height NS 35/7,5
[mm] 8.2 64 53.8
Dimensions Width Length Height NS 32
[mm] 8.2 64 58.8
Max. electrical data I
max.
[A] U
max.
[V] Max. Ø [mm²] AWG (UL)
30
2
) 250
3
) 0.2 - 10 26-8
Rated data IEC UL CSA IEC/
EN60079-7
Rated voltage [V] 250
3
) 300 32 -
Nominal current / cross section [A] / [mm²] 30
1
) / 4 30 / - 30 / - -
Rated cross section [mm²] 6 - - -
Cross section range AWG 24 - 8 26-8 26-8 -
Connection capacity Solid Stranded Ferrule
without/with plastic sleeve
1 conductor [mm²] 0.2 - 10 0.2 - 6 0.25 - 6 0.25 - 4
2 conductors (of the same type) [mm²] 0.2 - 2.5 0.2 - 2.5 0.25 - 2.5 -
2 stranded conductors with a TWIN ferrule [mm²] - - - 0.5 - 4
General data
Fuse type / dimensions – / [mm] C
Stripping length [mm] 10
Screw thread M4
Tightening torque [Nm] 1.5 - 1.6
Insulating material PA
Inflammability class according to UL 94 V0
Ordering data
Description
No. of
pos.
Color Type I
max
Order No.
Pcs. /
Pkt.
Fuse terminal block, for mounting on NS32... or
NS35...
black UK 6-FSI/C 3118203 50
Fuse terminal block, for mounting on NS32... or
NS35..., with LED for 12VDC, 1.7mA
1
)
black UK 6-FSI/C-LED12 3001925 50
With LED display for 24 V DC, 1.9mA
1
) black UK 6-FSI/C-LED24 3001938 50
Accessories
Fixed bridge, insulated
10 silver FBI 10- 8 34 A 0203263 10
Insertion bridge, fully insulated
2 gray EB 2- 8 57 A 0202154 100
3 gray EB 3- 8 57 A 0202141 100
4 gray EB 4- 8 57 A 0202142 100
10 gray EB 10- 8 57 A 0202138 10
Isolator bridge bar, can be separated, with 10 screws, for
switchable branches with IS-K...
10 silver ISSBI 10- 8 38 A 0301534 10
Bridge bar isolator, as distance piece for isolator
bridge bar
gray IS-K 10 1303337 100
Separating disk, for separation of neighboring
bridges, can be fitted later, no loss of pitch
gray TS-KK 3 2770215 50
Screwdriver SZS 1,0X4,0 VDE 1205066 10
Lateral groove marking ZB 8 (see Catalog 5)
401
PHOENIX CONTACT
– Compact fuse terminal block for type C
automatic flat-type fuses
– Available with LED display for rapid error
diagnostics
– Bridgeable with FBI ... fixed bridge
– Large marking option of every terminal
point
– Can be used as the basic terminal block
for thermal circuit breaker TCP.../DC32V;
see Catalog 6
– Type F auto flat-type fuse terminal blocks
are also available in the section entitled
“PT... push-in connection terminal blocks”
Fuse terminal block UK6-FSI/C, for
type C flat-type fuses
Terminal blocks
UK universal terminal blocks
6 (10) mm², 30 A, fuse terminal block for type
C flat-type fuses
Notes:
1
) If the fuse is faulty, the downstream circuit is not off load.
2
) For derating curve, visit phoenixcontact.net/products
3
) The current and voltage are determined by the fuse.
For corresponding fuse inserts, see Catalog 6.
The recommended continuous load capacity of the fuse inserts
according to DIN72581/Part3 is max. 80percent of their nominal
current (at an ambient temperature of 23°C)