Datasheet
For further information and full technical data, visit phoenixcontact.net/products
Technical data
1
) Technical data
1
)
Dimensions Width Length Height Width Length Height
[mm] 6.2 61.5 62.5 (NS 35/7,5) 6.2 61.5 62.5 (NS 35/7,5)
Max. electrical data I
max.
[A] U
max.
[V] max. Ø [mm²] AWG (UL) I
max.
[A] U
max.
[V] max. Ø [mm²] AWG (UL)
6.3
3
) 500
3
) 0.08 - 6 28-10 20 500 0.08 - 6 -
Max. bridge current [A] 32 (FBS) / 24 (FBSR) 32 (FBS) / 24 (FBSR)
Rated data IEC UL / CUL CSA Ex IEC UL / CUL CSA Ex
Rated voltage [V] 500
3
) 300 300 - 500 - - -
Nominal current / cross section [A] / [mm²] 6.3
3
) / 1 10 / - 6.3 / - - 20 / 2.5 - - -
Ordering data Ordering data
Description Color Type Order No.
Pcs. /
Pkt.
Type Order No.
Pcs. /
Pkt.
Fuse terminal block black ST 4-HESI (5X20) ① 3036369 50
With LED for 12 – 30 V DC, 0.31 – 0.95mA
2
) black ST 4-HESILED 24 (5X20) ② 3036547 50
for 30 – 60VAC/DC, 0.40 – 0.86mA
2
) black ST 4-HESILED 60 (5X20) ② 3036550 50
110 – 250VAC/DC, 0.41 – 0.96mA
2
) black ST 4-HESILA 250 (5X20) ② 3036563 50
Disconnect terminal block black/orange ST 4-HEDI ① 3035140 50
Terminal blocks - CLIPLINE complete
4 mm ST... spring-cage connection terminal blocks
6.3 A, lever-type fuse terminal block,
for 5 x 20 mm cartridge fuses
20 A, lever-type disconnect terminal block,
same shape
②
①①
Fuse terminal blocks and lever-type
disconnect terminal blocks of the
same shape
Notes:
1
) For additional accessories and technical data, see page 186.
2
) If the fuse is faulty, the downstream circuit is not off load.
3
) The current is determined by the fuse used, the voltage by the
selected light indicator. Observe the maximum power dissipation,
see phoenixcontact.net/products.
For the derating curve, see phoenixcontact.net/products
Technical data
1
) Technical data
1
)
Dimensions Width Length Height Width Length Height
[mm] 8.2 76.5 69 (NS 35/7,5) 8.2 86.5 43.5 (NS 35/7,5)
Max. electrical data I
max.
[A] U
max.
[V] max. Ø [mm²] AWG (UL) I
max.
[A] U
max.
[V] max. Ø [mm²] AWG (UL)
10
4
) 400 0.08 - 6 28-10 30
3
) 400
4
) 0.08 - 6 28-10
Max. bridge current [A] 32 (FBS) 41 (FBS)
Rated data IEC UL / CUL CSA Ex IEC UL / CUL CSA Ex
Rated voltage [V] 400 300 300 - 400
4
) 300 300 -
Nominal current / cross section [A] / [mm²] 10
4
) / 1.5 15 / - 10 / - - 30
4
) / 4 30 / - 10 / - -
Ordering data Ordering data
Description Color Type Order No.
Pcs. /
Pkt.
Type Order No.
Pcs. /
Pkt.
Fuse terminal block black ST 4-HESI (6,3X32) ① 3036385 50
With LED for 12 – 30VAC/DC, 0.31 – 0.95mA
2
) black ST 4-HESILED 24 (6,3X32) ② 3038765 50
110 – 250VAC/DC, 0.41 – 0.96mA
2
) black ST 4-HESILA 250 (6,3X32) ② 3038778 50
Fuse terminal block, for flat-type fuses black ST 4-FSI/C ① 3036372 50
With light indicator for 12VDC, 1.7mA
2
) black ST 4-FSI/C-LED 12 ② 3036495 50
With light indicator for 24 V DC, 1.9mA
2
) black ST 4-FSI/C-LED 24 ③ 3036505 50
189
PHOENIX CONTACT
10 A, lever-type fuse terminal block,
for 6.3 x 32 mm cartridge fuses
30 A, fuse terminal block for type C flat-type
fuses
②
①①
②
③
Fuse terminal blocks
Notes:
1
) For additional accessories and technical data, see page 186.
2
) If the fuse is faulty, the downstream circuit is not off load.
3
) For derating curve, visit phoenixcontact.net/products
4
) The current is determined by the fuse used, the voltage by the
selected light indicator. Observe the maximum power dissipation,
see phoenixcontact.net/products.
The recommended continuous load capacity of the fuse-links
according to DIN72581/Part3 is max. 80percent of their nominal
current (at an ambient temperature of 23°C)