Datasheet

Technical data
General data
Material PA
Inflammability class according to UL 94 V2
Temperature range [°C] -40 ... 100
Components free from silicone and halogen
Ordering data
Description Color Type Order No.
Pcs. /
Pkt.
Double marker carrier, can be snapped into push-in double-level
terminal blocks PTTB 1,5/S, can be labeled with ZB 3,5 or ZBF 3,5
gray STP 3,5-2 0830131 100
Triple marker carrier, can be snapped into the push-in three-level
terminal block PT 1,5/S-3..., can be labeled with ZB 3,5 or ZBF 3,5
gray STP 3,5-3 0830132 100
Double marker carrier, can be snapped into the double-level
terminal blocks STTB1,5, PTTB1,5, can be labeled with UC-TM4,
ZB4 or UC-TMF4, ZBF4
gray STP 4-2 0810575 100
Double marker carrier, can be snapped into STTB 2.5, STTB 4,
PTTB 2.5, PTTB 4 double-level terminal blocks, can be labeled with
UC-TM5, ZB5 or UC-TMF5, ZBF5
gray STP 5-2 0800967 100
Three-compartment marker carrier, can be snapped into
ST2,5–3... and PT2,5–3... three-level terminal blocks, can be
labeled with UC–TMF5 and ZBF5 or ...TM 5 and ZB 5
gray STP 5-3 0810562 100
Double marker carrier, snaps into double-level fast connection
terminal blocks, QTTCB ... and QTTCBS, can be labeled with ZB 5
and ZBF 5
gray STP 5-2/S 0800970 100
Double marker carrier, snaps into all terminal blocks with a width
of 4.2 mm and a Zack marker strip center groove, can be labeled
with ZB 4 or ZBF 4
gray STP 4-2-ZB 3038613 100
Double marker carrier, can be snapped into all terminal blocks
with a width of 5.2mm or above and a zack marker strip center
groove, can be marked with ZB5 or ZBF5
gray STP 5-2-ZB 3037643 100
Marker adapter, 300mm long, can be snapped into the lateral
groove on terminal blocks, designed to accommodate ZB... or
UC–TM...
gray CARRIER-TM 300 0828282 25
Marker adapter, double row, 300mm long, can be snapped into
the center groove on terminal blocks, designed to accommodate
two ZB... or UC–TM...
gray CARRIER-TMD 300 0828693 25
Marker adapter, such as the CARRIER-TM 300; marking area at
an angle to the top of the terminal block
gray CARRIER-TMH 300 0830670 25
352
PHOENIX CONTACT
STP...
The marking areas of wired multiple-level
terminal blocks are increased in size using
the marker carriers
Depending on version, the marker
carriers are placed in the receivers on the
upper terminal block level
STP...-ZB
The marker carriers can for example snap
into the center marking groove of ST
spring-cage terminal blocks and double
the marking area; see figure below
CARRIER-TM 300
Can be snapped into all terminal blocks in
the CLIPLINE complete system that have
a lateral flat marker groove
For accommodating ZB..., UC-TM... or
UCT-TM... terminal markers which
increases the marking area
CARRIER-TMD 300
Double-row snap-in marker adapter for
accommodating two ZB... or UC–TM...
and UCT-TM... terminal markers which
doubles the marking area
Marker carrier for STP... multi-level
terminal blocks
Terminal blocks - CLIPLINE complete
Accessories
Marker carriers