Datasheet

Technical data
Max. electrical data I
max.
[A] U
max.
[V] Max. Ø [mm²] AWG (UL)
30 400
2
) 0.2 - 10 - 30 400
IEC 60947-7-1
Rated data IEC UL CSA IEC/
EN60079-7
Rated voltage [V] 400
2
) - - - 400
Nominal current / cross section [A] / [mm²] 24
1
) / 6--- 24
Rated cross section [mm²]6--- 6--- 6--- 6---
Cross section range AWG 24 - 8 - - - 24 - 8 24 - 8 - - 24 - 8 24 - 8 - - 20 - 14 - - -
Connection capacity Solid Stranded Ferrule
without/with plastic sleeve
1 conductor [mm²] 0.2 - 10 0.2 - 10 0.25 - 6 0.25 - 6 0.2 - 10 0.2 - 10 0.25 - 6 0.25 - 6 0.2 - 10 0.2 - 10 0.25 - 6 0.25 - 6 - 0.5 - 2.5 - -
2 conductors (of the same type) [mm²] 0.2 - 2.5 0.2 - 2.5 0.25 - 1.5 - 0.2 - 2.5 0.2 - 2.5 0.25 - 1.5 - 0.2 - 2.5 0.2 - 2.5 0.25 - 1.5 - - - - -
2 stranded conductors with a TWIN ferrule [mm²] - - - 0.5 - 2.5 - - - 0.5 - 2.5 - - - 0.5 - 2.5 - - - -
General data
Stripping length [mm] 12
Tightening torque for wall fastening [Nm] 0.8 - 1
Panel thickness [mm] 1 - 4
Tightening torque: test socket screw [Nm] -
Insulating material PA
Inflammability class according to UL 94 V0
Ordering data
Description Color Type Order No.
Pcs. /
Pkt.
Test terminal strip, wall mounting gray UTWE 6-2/A7 3069410 1
Test terminal strip, DIN rail mounting gray UTRE 6-2/A7 3069423 1
Test plug, with twist grip, A7 coding gray
B7 coding gray
E7 coding gray
Test plug, with standard grip, A7 coding gray
B7 coding gray
E7 coding gray
Test plug, 1-pos., with cover red
Blind plug, sealable, A14 coding gray
B14 coding gray
C14 coding gray
550
PHOENIX CONTACT
Test terminal strip, with screw
connection, wall or DIN rail mounting
The VDEB7 version is suitable as a plug-
in test system in digital differential
protection as an addition to the F19 plug-in
test system, see page 546.
The VDEA7 version is suitable as a plug-
in test system in single-system current,
voltage, and power relays, wattmetric and
ground fault wiper relays, detuning level
controllers or reverse power protection for
generators.
The VDE E7 version is suitable as a plug-
in test system for single-stage automatic
frequency discharge and as rotor ground
fault protection.
The test plugs are assembled with
jumpers and contact tab lengths
according to the circuit diagram
A transparent covering hood protects the
jumpers. The covering hood can only be
removed by dismantling the test plug
All VDE-specified 7, 14, and 19-pos.
versions are supplied with exclusive
coding for the matching test plug and
blind plug
The components are supplied pre-marked
according to the VDE Directive
Test signals can be connected with touch-
proof safety test leads (CATIII and
IV/1000V according to EN61010-031)
The test plugs are equipped with two gray
test sockets per position, for further
color versions, see the range of
accessories
Blind plug
The FBP-2.. blind plug is an optional
protective cover for the test terminal strip
and is characterized by:
Secure, sealable latching on the test
terminal strip
Can only be removed by means of two-
hand operation
Large marking option
Blind plug, 7-pos., VDE coded
Sector-specific solutions
Solutions for energy technology
Notes:
To create panel cutouts, see phoenixcontact.net/products.
1
) Derating curve available on request.
2
) Rated surge voltage of 5 kV.
6 (10) mm², 30A, test terminal strip, VDE
coded type A7