Datasheet

https://www.phoenixcontact.com/us/produkte/2964636
Nov 9, 20132/7
Solid-state relay terminal block-DEK-OV-
12DC/240AC/800-2964636
Technical data
Input data
Switching threshold "1" signal in reference to U
N
≥ 0.8
Typical input current at U
N
10.5 mA
Typical response time
< 10 ms
Typical turn-off time
< 10 ms
Operating voltage display
Yellow LED
Type of protection
Protection against polarity reversal
Type of protection
Surge protection
Protective circuit/component
Polarity protection diode
Transmission frequency
10 Hz
Output data
Output voltage range
10 V AC ... 253 V AC (50/60 Hz)
Limiting continuous current
0.8 A (see derating curve)
Maximum inrush current
30 A (t = 10 ms)
Min. load current
10 mA
Leakage current
1.2 mA (in off state)
Max. load value
4.5 A
2
s
Peak offstate voltage
600 V (Periodic peak reverse voltage)
Voltage drop at max. limiting continuous current
≤ 1 V
Output circuit
2-conductor floating, zero voltage switch
Type of protection
RCV circuit
Protective circuit/component
RCV circuit
Connection data
Connection method
Screw connection
Stripping length
8 mm
Screw thread
M3
Conductor cross section solid min.
0.2 mm²
Conductor cross section solid max.
4 mm²
Conductor cross section stranded min.
0.2 mm²
Conductor cross section stranded max.
2.5 mm²
Conductor cross section AWG/kcmil min.
24
Conductor cross section AWG/kcmil max
12
General
Test voltage input/output
2.5 kV AC
Mounting position
Any
Assembly instructions
In rows with zero spacing
Operating mode
100% operating factor
Name
Standards/regulations
Standards/regulations
IEC 60664