Datasheet

https://www.phoenixcontact.com/us/produkte/2819587
Nov 13, 20132/6
Inline function terminal-IB IL EC AR 48/10A-PAC-2819587
Technical data
Interfaces
Name
Inline local bus
Connection method
Inline data jumper
Transmission speed
500 kBit/s
Name
Startup and diagnostics
Connection method
RS-232
Power supply for module electronics
Connection method
2-pos. COMBICON connector
Name
Power supply
Supply voltage range
12 V DC ... 48 V DC ±15% (Surge voltage shutdown U
S
> 60 V
DC)
Max. current carrying capacity
10 A
Motor starter, output
Connection method
4-pos. COMBICON plug with shield connection clamp
Number
1
Output name
1 permanently excited DC motor with or without brushgear
Number of positions
4
Nominal current range
max. 10 A (Starting/continuous current)
Digital inputs
Number of inputs
3
Connection method
MINI COMBICON
Connection method
3-wire (Signal, Us, GND)
Number of positions
3
Input voltage
24 V DC
Inline potentials
Communications power U
L
7.5 V DC (via voltage jumper)
Current consumption from U
L
typ. 30 mA
Current consumption from U
L
max. 120 mA
Main circuit supply U
M
24 V DC (via voltage jumper)
Current consumption from U
M
typ. 100 mA
Current consumption from U
M
max. 150 mA
Segment supply voltage U
S
24 V DC (via voltage jumper)
General
Weight
880 g
Note on weight specifications
with male connectors
Mounting type
DIN rail
Protection class
III, IEC 61140, EN 61140, VDE 0140-1
Test section
Logic UL / I/O / motor 500 V AC
Conformance with EMC directives
Noise immunity test in accordance with EN 61000-6-2 Discharge
of electrostatic electricity (ESD) EN 61000-4-2:1995/IEC