Datasheet

https://www.phoenixcontact.com/us/produkte/2800792
Nov 13, 20132/8
Surge protection device-PT-IQ-1X2+F-5DC-UT-2800792
Technical data
General
Inflammability class according to UL 94
V0
Color
black
Mounting type
DIN rail mounting
Design
DIN rail module, two-section, divisible
Direction of action
Line-Line & Line-Signal Ground/Shield & optional Signal Ground/
Shield-Earth Ground
Protective circuit
IEC test classification
C1
IEC test classification
C2
IEC test classification
C3
IEC test classification
D1
Nominal voltage U
N
5 V DC
Maximum continuous operating voltage U
C
6 V DC
Maximum continuous operating voltage U
C
4 V AC
Nominal current I
N
1000 mA (Up to 45°C)
Operating effective current I
C
at U
C
≤ 2 mA (per system)
Residual current I
PE
≤ 1 µA
Nominal discharge current I
n
(8/20) µs (Core-Core)
10 kA
Nominal discharge current I
n
(8/20) µs (Core-Earth)
10 kA
Total surge current (8/20) µs
20 kA
Impulse discharge current (10/350) µs, peak value l
imp
2.5 kA
Voltage protection level U
P
(Core-Core)
≤ 85 V (C1 - 1 kV/500 A)
Voltage protection level U
P
(Core-Core)
≤ 110 V (C2 - 10 kV / 5 kA)
Voltage protection level U
P
(Core-Core)
≤ 140 V (C2 - 10 kA)
Voltage protection level U
P
(Core-Core)
≤ 25 V (C3 - 25 A)
Voltage protection level U
P
(Core-Core)
≤ 25 V (C3 - 50 A)
Voltage protection level U
P
(Core-Earth)
≤ 900 V (C1 - 1 kV/500 A)
Voltage protection level U
P
(Core-Earth)
≤ 1300 V (C2 - 10 kV / 5 kA)
Voltage protection level U
P
(Core-Earth)
≤ 1200 V (C2 - 10 kA)
Voltage protection level U
P
(Core-Earth)
≤ 1000 V (C3 - 25 A)
Voltage protection level U
P
(Core-Earth)
≤ 1300 V (C3 - 100 A)
Voltage protection level U
P
(Core-GND)
≤ 600 V (C1 - 1 kV/500 A)
Voltage protection level U
P
(Core-GND)
≤ 750 V (C2 - 10 kV / 5 kA)
Voltage protection level U
P
(Core-GND)
≤ 800 V (C2 - 10 kA)
Voltage protection level U
P
(Core-GND)
≤ 700 V (C3 - 50 A)
Voltage protection level U
P
(Core-GND)
≤ 800 V (C3 - 100 A)
Voltage protection level U
P
static (core-core)
≤ 26 V (C1 - 1 kV/500 A)
Response time tA (Core-Core)
≤ 1 ns
Response time tA (Core-Earth)
≤ 100 ns
Response time tA (Core-Earth)
≤ 100 ns