Brochure

PHOENix CONTACT 9
Lateral load of 200 N
Test against dynamic lateral load
In accordance with
DIN IEC60512-5
During installation, the housings
may be partially subjected to high
static loads. In this test, a force of
200 N is applied to the cable in 50
cycles. The effect of the force on the
locking mechanism and cable gland is
particularly detrimental at an angle
of90°.
This test verifies that the
HEAVYCONEVO bayonet locking and
the double locking latch between the
housing and panel mounting frame do
not open independently or malfunction
even in the case of extreme loads.
Extreme load due to roll-over with a forklift
truck
Roll-over test
In accordance with
DIN IEC62196-1
Housings that are removed during
servicing or installation may be
subjected to high stresses from moving
loads such as heavy pallets or vehicles
such as forklift trucks.
A special test is carried out on the
EVO housing where a forklift truck
weighing several tons is rolled over the
housing.
HEAVYCON EVO housings withstand
high stresses from heavy, moving loads
without any adverse effect on function
and are therefore ideal for use in
industrial environments.
Impact of falling hammer weighing 1.7 kg
IK08 shock resistance test
DIN EN 50102
During use, housings may be subjected
to shock and impact, for example, from
falling tools. Testing is carried out with
a freefalling hammer weighing 1.7kg,
which is dropped onto the housing five
times from a height of 0.3 meters. This
is to ensure that no damage is caused
which adversely affects function.
The plastic plug-in connectors have
IK08 shock resistance, which is the
same as that of aluminum plug-in
connectors or aluminum control boxes,
and therefore meet the mechanical
requirements of heavy-duty industrial
plug-in connectors.