Technical data
Material
Material of grip body
TPU, hardly inflammable, self-extinguishing
Material, knurls
Zinc die-cast, nickel-plated
Sealing material
NBR
Cable
Cable type
PROFIBUS
Cable type (abbreviation)
910
UL AWM style
21198 (80°C/300 V)
Conductor cross section
2x 0.25 mm² (signal line)
AWG signal line
24
Conductor structure signal line
19x 0.13 mm
Core diameter including insulation
2.55 mm ±0.07 mm
Wire colors
Red, green
Overall twist
2 cores with 2 fillers to the core
Shielding
Plastic-coated aluminum foil, tinned copper braided shield
Optical shield covering
85 %
External sheath, color
Violet, RAL 4001
External cable diameter D
7.8 mm ± 0.2 mm
Number of bending cycles
4000000
Bending radius
65 mm
Traversing path
4.5 m
Traversing rate
3 m/s
Acceleration
3 m/s²
Max. bending cycles
5000000
Bending radius
80 mm
Traversing path
4.5 m
Traversing rate
3 m/s
Acceleration
3 m/s²
Outer sheath, material
PUR
Material conductor insulation
Foamed PE
Conductor material
Tin-plated Cu litz wires
Insulation resistance
≥ 5 GΩ*km
Conductor resistance
157.2 Ω/km
Working capacitance
30 nF
Wave impedance
nom. 150 Ω ±10 % (3 MHz ... 20 MHz)
Shield attenuation
≤ 4.9 dB (at 16 MHz)
Nominal voltage, cable
30 V
Test voltage Core/Core
1500 V (50 Hz, 1 min.)
Test voltage Core/Shield
1500 V (50 Hz, 1 min.)
Flame resistance
UL 1581, Sec. 1060 (FT-1)
Flame resistance
IEC 60332-1
Other resistance
Low adhesion