User's Manual
Table Of Contents
- Instructions for Use
- 1 Introduction and Basic Operation 7
- 2 Monitoring with the IntelliVue Cableless Measurements 19
- 3 Monitoring SpO2 25
- 4 Monitoring NBP 33
- 5 Technical Alarms (INOPs) 41
- 6 Care and Cleaning 47
- 7 Maintenance and Troubleshooting 51
- 8 Integrated Battery Handling 53
- 9 Accessories 55
- 10 Specifications 59
- Index 73
- Introduction and Basic Operation
- Introducing the IntelliVue Cableless Measurements
- Operating and Navigating
- Switching the Devices On and Off
- Screen Layout
- Standard Layout
- 1 Connection status indicator
- 2 Indicator that alarming capability has been transferred to the host (to the monitor or, for the telemetry device, to the Information Center). No patient alarms will be announced on the Cableless Measurement Device.
- 3 Battery indicator
- 4 Measurement values
- 5 Measurement-related symbols (see the measurement chapters for details)
- 6 Patient identification (from a monitor or telemetry device)
- 1 Connection status indicator
- 2 Battery indicator
- 3 Measurement values
- 4 Measurement-related symbols (see the measurement chapters for details) The Alarms Off symbols indicate that no physiological alarms are available from the Cableless Measurement Devices when not assigned to a host.
- 5 Patient identification (from a monitor or telemetry device)
- INOP Layout
- Low-Activity Screen
- Standard Layout
- When a Cableless Measurement Device Cannot be Activated
- Using the Hard Keys
- Using the SmartKeys
- Using the Main Setup Menu
- Operating Modes
- Using the Patient Menu
- Using Profiles
- Setting the Date and Time
- Charging IntelliVue Cableless Measurement Devices
- Monitoring with the IntelliVue Cableless Measurements
- Monitoring SpO2
- NOTE
- SpO2 Sensors
- Connecting SpO2 Sensors
- 1 Connect the sensor to the single patient Mobile CL SpO2 Cradle (if not already connected).
- 2 Insert the SpO2 Pod into the Mobile CL SpO2 Cradle. The correct orientation is indicated by a matching blue dot inside the cradle.
- CAUTION
- Removing the Pod from the Cradle
- Applying the Sensor
- 1 Choose a finger of the patient that matches the sensor dimension in a way that the sensor optical components are properly aligned and the sensor is neither too loose nor applies too much pressure to the finger. For small pediatric patients consider...
- 2 Remove colored nail polish from the application site.
- 3 Apply the sensor to the patient. The application site should match the sensor size so that the sensor can neither fall off, nor apply excessive pressure. See the sections below for details on applying the different sensors.
- 4 Check that the light emitter and the photodetector are directly opposite each other. All light from the emitter must pass through the patient's tissue.
- WARNING
- Measuring SpO2
- Selecting Measurement Modes
- Understanding SpO2 Numerics and Symbols
- Assessing a Suspicious SpO2 Reading
- Changing the Averaging Time
- Understanding SpO2 Alarms
- Perfusion Numeric (only available on the Patient Monitor)
- Monitoring NBP
- Introducing the Oscillometric NBP Measurement
- Preparing to Measure NBP
- 1 Attach the cradle to the NBP cuff and insert the NBP Pod into the cradle.
- 2 Plug the air tubing into the NBP Pod. Hold the flat part of the connector vertically when plugging it into the inlet, then twist it clockwise to lock into place. Avoid compression or restriction of pressure tubes. Air must pass unrestricted through...
- 3 Make sure that you are using a Philips-approved correct sized cuff and that the bladder inside the cover is not folded or twisted.
- 4 Apply the cuff to the upper arm at the same level as the heart. If it is not at heart level, you must use the measurement correction formula to correct the measurement.
- CAUTION
- Additional Information
- Using a Carrying Pouch
- 1 Apply the cuff as described in step 4 above.
- 2 Secure the pouch on the patient, with the upper ties around the patient's head and arm and the lower ties around the patient's torso.
- 3 Insert the NBP Pod into the cradle.
- 4 Attach the extension hose to the NBP Pod in the cradle.
- 5 Insert the NBP cradle into the pouch
- 6 Connect the extension hose to the cuff.
- Starting and Stopping Measurements
- Enabling Automatic Mode and Setting Repetition Time
- Enabling Sequence Mode and Setting Up The Sequence
- 1 In the NBP menu, select Mode and select Sequence from the pop-up menu.
- 2 Select Setup Sequence to open the Setup Sequence menu.
- 3 Select each phase in turn (A, B, C and D) and select the number of measurements and the time interval between the measurements.
- 4 To have measurements continue after the sequence, set the number of measurements for your last phase to Cont and this phase will run indefinitely.
- CAUTION
- Understanding the NBP Numerics and Symbols
- Correcting the Measurement if Limb is not at Heart Level
- Switching Pulse from NBP On/Off
- Assisting Venous Puncture
- Calibrating NBP
- Technical Alarms (INOPs)
- Care and Cleaning
- Maintenance and Troubleshooting
- WARNING
- Inspecting the Equipment and Accessories
- 1 Examine unit exteriors for cleanliness and general physical condition. Make sure that the housings are not cracked or broken, that everything is present, that there are no spilled liquids and that there are no signs of abuse.
- 2 Inspect all accessories (cables, sensors and so forth). If any show signs of damage, do not use them.
- WARNING
- Maintenance Task and Test Schedule
- Troubleshooting
- Disposing of the IntelliVue Cableless Measurement Devices
- Integrated Battery Handling
- Accessories
- Specifications
- WARNING
- Intended Use
- Manufacturer's Information
- Symbols
- Installation Safety Information
- Safety Specifications
- EMC And Radio Regulatory Compliance
- IntelliVue CL SpO2 Pod Specifications
- IntelliVue CL NBP Pod Specifications
- Alarm Specifications
- Telemetry Device Battery Runtime Specifications
- IntelliVue CL Charging Station Specifications
- IntelliVue CL Transmitter Base Station Specifications
- Safety and Performance Tests
- Electromagnetic Compatibility (EMC) Specifications
- Accessories Compliant with EMC Standards
- Electrosurgery Interference/Defibrillation
5 Technical Alarms (INOPs)
42
Setting the Volume of the INOP Tone
To set the volume for the INOP tone,
1 Select the Main Setup SmartKey.
2 Select INOPs.
3 Select Inop Vol and select a volume setting.The maximum is 10 and the minimum depends on
your configuration.
Reference List of all INOPs
INOP Message, Indication Source What to do
Batt Incompatible
INOP tone
Battery Battery cannot be used with this Cableless Measurement
Device. Replace battery with one that has been approved
for use with this Cableless Measurement Device. Contact
your service personnel.
Batt Malfunction
INOP tone
Battery Malfunction of the battery system detected (charger
circuit or battery). Contact your service personnel.
Battery Empty
INOP tone
Battery The remaining monitoring time is below 30 minutes.
Charge battery.
Battery Low
INOP tone
Battery The remaining monitoring time is below 2 hours.
Check Batt Temp
INOP tone
Battery The temperature of the battery is critically high. Check
that Cableless Measurement Device is not covered and
not exposed to a heat source. If INOP persists, remove
Cableless Measurement Device from patient and contact
your service personnel.
Check Battery
INOP tone
Battery The maximum number of charge/discharge cycles of the
battery will be reached in less than 50 cycles. Contact
your service personnel to replace the battery.
Check Charger I/F
INOP tone
Battery Overvoltage or undervoltage detected at the charger
interface. Clean contacts of charger interface at Cableless
Measurement Device and charging station. If the INOP
persists, contact your service personnel.
Check Settings
INOP tone
Cableless
Measurement Device
If this INOP appears and an INOP tone sounds, check
the Cableless Measurement Device and patient settings
before you resume making measurements. If the settings
are unexpected, there may be a problem with the
Cableless Measurement Device software. Contact your
service personnel.
If this INOP is acknowledged at the Cableless
Measurement Device, it is cleared. If it is silenced
remotely, only the tone is cleared.