Datasheet

Filterfans
Filterfans
162 163
Further technical information can be found on the Internet: www.pfannenberg.comwww.pfannenberg.com
Filterfan
PF 66.000
Exhaust lter
PFA 60.000
Data PF 66.000
Unit
Article number
IP 54 11666022055 11666102055 11666152055
IP 55 11666023055 11666103055 11666153055
Rated voltage ± 10%
AC 50 Hz / 60 Hz
400 / 460 3 ~ 230 115 V
Unimpeded airow
IP 54 640 / 653
m³/h
IP 55 770 / 785
Airow rate in combination
(PF + PFA 60.000)
IP 54 445 / 445
IP 55 490 / 501
Power consumption 120 / 155 115 / 150 110 / 160 W
Current consumption 0.26 / 0.25 0.51 / 0.66 0.96 / 1.4 A
Noise level
(according to EN ISO 3741)
IP 54
63 / 64 dB (A)
IP 55
Weight 3.2 kg
Type of connection spring-type terminal
Fuse 6 A
System of protection
according to EN 60529 / UL 50
IP 54 NEMA type 12 - standard lter
IP 55 NEMA type 12 - uted lter
Filtration efciency
IP 54
91 %
IP 55
Filter mat quality class
according to EN 779
IP 54
G 4
IP 55
Duty cycle 100 %
Bearing type ball bearing
Service life L
10
(+ 40 °C)
1
40000 h
Temperature range - 40 … + 55 / - 40 … + 131 °C / °F
Design (housing and protection
against accidental contact)
IP 54 made of injection-moulded thermoplastic, self-extinguishing, UL 94 VO
IP 55 additional: UV-resistant
Colour RAL 7035, different colours available on request
Cooling capacity performance curves Static pressure performance curves
PF 66.000 IP 54
PF 66.000 IP 55
PF 66.000 IP 54
PF 66.000 IP 55
Kühlleistung
[W ]
0 5 10 15 20 25 30 35 4 0
T emperaturdif ferenz
Δ
T [K]
7000
6000
5000
4000
3000
2000
1000
0
PF 66.000 IP54 / PF A 60.000 IP54
PF + 2 P FA
Kühlleistung
[W ]
0 5 10 15 20 25 30 35 4 0
T emperaturdif ferenz
Δ
T [K]
700 0
600 0
500 0
400 0
300 0
200 0
100 0
0
PF 66.000 IP55 / PF A 60.000 IP55
PF + 2 P FA
Kühlleistung
[W ]
0 5 10 15 20 25 30 35 4 0
T emperaturdif ferenz
Δ
T [K]
9000
8000
7000
6000
5000
4000
3000
2000
1000
0
PF 67.000 IP54 / PF A 60.000 IP54
PF + 2 P FA
Kühlleistung
[W ]
0 5 10 15 20 25 30 35 4 0
T emperaturdif ferenz
Δ
T [K]
900 0
800 0
700 0
600 0
500 0
400 0
300 0
200 0
100 0
0
PF 67.000 IP55 / PF A 60.000 IP55
PF + 2 P FA
PF + PFA
PF + PFA
PF + PFA
PF + PFA
Kühlleistung
[W ]
0 5 10 15 20 25 30 35 4 0
T emperaturdif ferenz
Δ
T [K]
7000
6000
5000
4000
3000
2000
1000
0
PF 66.000 IP54 / PF A 60.000 IP54
PF + 2 P FA
Kühlleistung
[W ]
0 5 10 15 20 25 30 35 4 0
T emperaturdif ferenz
Δ
T [K]
700 0
600 0
500 0
400 0
300 0
200 0
100 0
0
PF 66.000 IP55 / PF A 60.000 IP55
PF + 2 P FA
Kühlleistung
[W ]
0 5 10 15 20 25 30 35 4 0
T emperaturdif ferenz
Δ
T [K]
9000
8000
7000
6000
5000
4000
3000
2000
1000
0
PF 67.000 IP54 / PF A 60.000 IP54
PF + 2 P FA
Kühlleistung
[W ]
0 5 10 15 20 25 30 35 4 0
T emperaturdif ferenz
Δ
T [K]
900 0
800 0
700 0
600 0
500 0
400 0
300 0
200 0
100 0
0
PF 67.000 IP55 / PF A 60.000 IP55
PF + 2 P FA
PF + PFA
PF + PFA
PF + PFA
PF + PFA
PF 66.000 IP54 / PF A 60.000 IP54
Statischer Druck
[Pa]
01 00 20 03 00 40 05 00 60 07 00 80 0
445 524 640
134
Luftfördermenge [m
3
/h]
150
125
100
75
50
25
0
2 PF A
PF A
PF
PF 66.000 IP55 / PF A 60.000 IP55
Statischer Druck
[Pa]
01 00 20 03 00 40 05 00 60 07 00 80 0
490 556 770
134
Luftfördermenge [m
3
/h]
150
125
100
75
50
25
0
2 PF A
PF A
PF
PF 67.000 IP54 / PF A 60.000 IP54
Statischer Druck
[Pa]
0 100 2 00 300 400 500 600 700 800 900
560 682 845
192
Luftfördermenge [m
3
/h]
200
175
150
125
100
75
50
25
0
2 PF A
PF A
PF
PF 67.000 IP55 / PF A 60.000 IP55
Statischer Druck
[Pa]
0 10 0 2 00 30 0 400 500 600 700 800 900 1000
570 925
187
Luftfördermenge [m
3
/h]
200
175
150
125
100
75
50
25
0
2 PF A
PF A
PF
PF 66.000 IP54 / PF A 60.000 IP54
Statischer Druck
[Pa]
01 00 20 03 00 40 05 00 60 07 00 80 0
445 524 640
134
Luftfördermenge [m
3
/h]
150
125
100
75
50
25
0
2 PF A
PF A
PF
PF 66.000 IP55 / PF A 60.000 IP55
Statischer Druck
[Pa]
01 00 20 03 00 40 05 00 60 07 00 80 0
490 556
770
134
Luftfördermenge [m
3
/h]
150
125
100
75
50
25
0
2 PF A
PF A
PF
PF 67.000 IP54 / PF A 60.000 IP54
Statischer Druck
[Pa]
0 100 2 00 300 400 500 600 700 800 900
560 682 845
192
Luftfördermenge [m
3
/h]
200
175
150
125
100
75
50
25
0
2 PF A
PF A
PF
PF 67.000 IP55 / PF A 60.000 IP55
Statischer Druck
[Pa]
0 10 0 2 00 30 0 400 500 600 700 800 900 1000
570 925
187
Luftfördermenge [m
3
/h]
200
175
150
125
100
75
50
25
0
2 PF A
PF A
PF
Dimensions
A
B
Z1
Y
X
Z2
Accessories
Piece Article number Information on page
Exhaust lter PFA 60.000
IP 54 1 11760002055 190
IP 55 1 11760003055 190
Thermostat 1 17121000000 208/210
1
fan failure is dened as being when the current and speed deviate or the operating noises are out of the ordinary
Approvals see page 149.
1
for material thicknesses up to 2 mm
+ 1 mm for thickness of material > 2 mm ≤ 3 mm
mm
PF 66.000 PFA 60.000
X 320 320
Y 320 320
Z1 7 7
Z2 150 39
A
1
291 291
B
1
291 291
A
B
Z1
Y
Z2
X
• installation size 6, air ow rate up to 785 m
3
/h
• three performance classes, cut-out compatible
• system of protection IP 54 and IP 55, NEMA type 12
• UL, cUL approval
• UV-resistance (IP 55 version)
cut-out compatible with installation size 6 from the 3
rd
Generation
and with cooling unit DTFI 9021 (see page 40)
Static Pressure [Pa]
Cooling capacity [W]
Temperature difference ∆T [K]
Airow rate [m
3
/h]
Static Pressure [Pa]
Cooling capacity [W]
Temperature difference ∆T [K]
Airow rate [m
3
/h]

Summary of content (1 pages)