IRON & MANGANESE FILTER SYSTEM COMBO WF6-P | WF10-P pentair.
TABLE OF CONTENTS IMPORTANT INFORMATION ..................................................................................................................................................... 2 CUSTOMER SERVICE CONTACT INFORMATION ........................................................................................................................ 2 PRODUCT OPERATION AND SPECIFICATIONS .........................................................................................................................
PRODUCT OPERATION OPERATION AND AND SPECIFICATIONS SPECIFICATIONS PRODUCT WF6-P WF10-P Max Flow Rate 10 GPM 15 GPM Minimum Working Pressure 25 PSI Maximum Working Pressure 80 PSI Maximum Vacuum 5 inch/127 mm Hg Operating Temperatures 36°F – 120°F pH Range 7 - 11 POWER REQUIREMENTS The computer board receives power from an external wall-mount transformer, supplied with each system. Voltage: The voltage supplied to the computer board is 24V AC. Frequency: The line frequency is 50 Hz or 60 Hz.
Part Description Qty. Sediment Filter: 5-Micron Poly-Spun 1 Part Description Qty. Sediment Filter Wrench 1 Solution Tank 1 Chemical Injector Pump Tubing 1 Sediment Filter PVC Tubing Drain Line (50 ft.) Chlorine Test Strips Non-Abrasive Auto Wax 1 1 4 oz. Bottle Chemical Injector Pump (2) 1" Bushings Included 1 Pentair Whole House Iron & Manganese Filter 1 1 Pentair Whole House Carbon Filter 1 Note Drawings not to scale.
INSTALLATION OVERVIEW Wall Wall Wall IN Incoming Water Supply Outgoing Water to House OUT IN OUT Wall Outgoing Water to House Incoming Sediment Filter Water Supply Sediment Filter Top View Top View Injection Pump Water Softener Alternative Whole House Filter Iron Manganese Filter Iron Manganese Filter Whole House Filter Water Softener Alternative Bypass Injection Pump Bypass Water to Home Water to Home Sediment Filter Sediment Filter Iron Manganese Filter Iron Manganese Filter Fron
PRE-INSTALLATION Note Head may come loose in transit. Please check head by tightening clock wise, hand tighten only, no more than 1/4 turn. Head may not move at all or less than 1/4 turn. Bypass Valve Installation for the Whole House Carbon Filter Red Arrow T Quick Connect Nut INLET Water Filter Head OUTLET Top View Carbon Filter The bypass valve comes pre-assembled and ready to install with the o-rings, split rings, and quick connect nuts.
MEDIA SOAK Wall IN OUT Wall Incoming Water Supply 19” Sediment Filter Bypass Mode Top View Bypass Valve Water Garden Hose OUTLET Hose Bib Assembly INLET Top View Whole House Water Filter Carbon Soak/Rinse: Note Steps 1-3 should be done prior to installation 1. Locate the carbon filter tank and the hose bib attachment. 2. Attach the hose bib attachment to "Inlet" side of the carbon filter.
SEDIMENT FILTER INSTALLATION Note Sediment filter position is at the discretion of your professional installer. As a general guideline, the sediment pre filter is typically installed in the "pre" position (as shown above) for well-water applications. For city water applications, the sediment filter is typically installed in the "post" position after the Water Softener Alternative tank. Sediment Filter Sediment Filter Cover O-Ring x2 Blue Filter Housing Stand Pipe Part 1 1.
CHEMICAL INJECTOR PUMP AND SOLUTION TANK INSTALLATION Chemical Injector Pump Incoming Water Supply Chemical Injector Pump Tubing Outgoing Water to House Sediment Filter Front View 35 Gallon Solution Tank Pump Foot Valve Chemical Injector Pump Installation IMPORTANT Install the Chemical Injector Pump onto the water supply after the Sediment Filter and before any other filtration or softening system. 1.
Incoming Water Supply Drain Line Barb Chemical Injector Pump Tubing Outgoing Water to House IRON Sediment AND MANGANESE TANK INSTALLATION Filter Solution Tank Wall Wall Electronic Head Whole House Iron & Manganese Filter OUT IN Top View Incoming Water Supply Whole House Water Filter Outgoing Water to House Sediment Filter Top View Whole House Filter Iron Manganese Filter Water Softener Alternative 1. Level the Whole House Iron & Manganese Filter.
WHOLE Wall HOUSE WATER FILTER INSTALLATION 1. Level the Whole House Water Filter. Chemincal Injector Pump Spigot IN OUT Notice Wall Incoming Drain Line Water If the tank is not level, lift the tank straight up 6 inches and tap it on the ground until the tank stands Barb Supply vertical. The bottom of the tank is round and the boot allows the tank to stand upright.
BYPASS VALVE OPERATIONS In InService Service Figure A shows the system "in service" which allows water to flow in and out of the tank. In this position the system would be considered ON. Figure FigureAA In InBypass Bypass Figure B shows the system "in bypass" which will direct water straight to the home without going in and out of the tank. In this position the system would be considered OFF. Figure FigureBB COMPLETE THE INSTALLATION 1. Turn on main water supply 2.
PROGRAMMING THE ELECTRONIC HEAD How to Program the End User's Level To begin, verify that the control is in the Service Mode. Time of Day GL Remaining Press the SCROLL BUTTON to advance to the next setting. The following settings are available in the End User’s Level: 1. Time of Day The control will display: Set Time of Day • Press the UP or DOWN ARROW to program the time of day. Press the SCROLL BUTTON to advance to the next setting. Key Buttons: 2.
TESTING CHLORINE LEVELS IN WATER - DIALING IN 1. Put the Whole House Water Filter into bypass. (See page12 for bypass position) 2. Turn on the nearest cold water faucet to the system. 3. Listen and watch the pump to make sure it is pumping. The pump should pulse and not run continuously. If the water is off, the pump will stop. 4. Let the water run for 15 minutes. 5. After 15 minutes, use a chlorine test strip to test a sample of water from the cold water faucet. a. The optimum chlorine level reading is 2.
MAINTENANCE Sediment Filter It is recommended that the sediment filter be replaced every 6-9 months depending on the amount of sediment present in the water supply. If the system has been working properly and the pressure is slowing, it may be time to change the sediment filter. Check the sediment filter and replace if necessary. Sediment Filter Sediment Filter Cover O-Ring x2 Blue Filter Housing Stand Pipe Replacing the Sediment Filter 1.
ELECTRONIC VALVE MAINTENANCE REQUIREMENTS • Clean the backwash flow control. • Verify that the flow meter is functioning correctly. Clean the impeller, if necessary. • Verify the programming of the control. Reprogram, if necessary. • Verify the minimum and maximum water pressure. Install a pressure reducer, if necessary. • Replace the filter media every three to five years. Systems used for treatment of high iron willnrequire replacement of the filter media more often.
TROUBLESHOOTING Problem Solution Water leaking at the top of the tank around the head. You may need to turn the head to tighten it. The tank head is pre-installed hand-tight, do not overtighten the head (just turn it snug). The tank leans to one side or is not level. If the tank is not level, lift the tank straight up 6 inches and tap it on the ground until the tank stands vertical. The bottom of the tank is round and the boot allows the tank to stand upright.
Problem Solution The unit fails to regenerate. 1. Check the electrical items (fuse, transformer). 2. Verify the correct regeneration schedule and reset the control. 3. Replace the drive motor. 4. Replace the flow meter. 5. Replace the computer board. 6. Replace the microswitches. The valve cycles continuously. Replace the microswitches. Constant water flow to the drain. 1. Replace the drive motor. 2. Replace the computer board. 3. Replace the microswitch(es). 4. Defective microswitch(es).
PRODUCT CERTIFICATION Certified By IAPMO R&T to NSF/ANSI Standard 42 for the reduction of Chlorine Taste & Odor, structural integrity & NSF/ANSI 61 for material safety. The NaturSoft® system is DVGW DW-9191 certified for 99.6% hard water scale prevention.
2361 Mason Ave | Suite 100 | Daytona Beach, FL 32117 | United States P: 877.842.1635 | Technical Services: 877.842.1635 | pentair.com/homewater © 2021 Pentair. All indicated Pentair trademarks and logos are property of Pentair. Third party registered and unregistered trademarks and logos are the property of their respective owners.