Installation Instructions
PelPro Cast Pellet Stove • 7093-600 • 07/13/16pelprostoves.com 11
Installing Your Stove
• 45° elbow is equivalent to 1 foot of straight pipe
• 90° elbow is equivalent to 3 feet of straight pipe
Installing Your Stove
Notice:
T h ese are g u i d eli n es f or su ccessf u l ven ti n g of
y ou r pellet appli an ce. T h e more verti cal ri se
y ou can ob tai n i n y ou r sy stem, th e b etter i t w i ll
perf orm. H ori z on tal ven t ru n s can accu mu late
ash an d w i ll n eed to b e clean ed more of ten .
T ry to k eep th em as sh ort as possi b le.
Venting Your Stove
T h e maxi mu m h ori zo n tal ven ti n g allow ed w i th n o verti cal
venting attached is 48 inches including one 90° elbow
or two 45° elbows. Addition of any horizontal venting
beyond 48 inches requires a minimum 60 inches of
ad d i ti on al verti cal ven t. H ori zo n tal secti on s of ven t pi pe
sh ou ld h ave a 1/4 i n ch ri se per f oot. W e recommen d
u si n g th e sh ortest ven ti n g an d f ew est elb ow s possi b le
w h en ven ti n g h ori zo n tal.
W e recommen d th e u se of 4 i n ch ven t w i th an y
installation requiring more than two 90° elbows, or more
th an 15 f eet of ven ti n g .
M i n i m u m V e r t i c a l V e n t f o r O n e El b o w
0
5
1 0
1 5
2 0
0 5 1 0 1 5 2 0
H o r i z o n t a l R u n , ( f t )
M i n i m u m V e r t i c a l R i s e
( f t )
H o r i z o n t a l R u n ( F T )
M i n i m u m V e r t i c a l V e n t f o r O n e El b o w
0
5
1 0
1 5
2 0
0 5 1 0 1 5
M i n i m u m V e r t i c a l
R i s e , ( f t )
M i n i m u m V e r t i c a l V e n t f o r T w o El b o w s
L e n g t h o f H o r i z o n t a l S e c t i o n s ( F T )
0
5
1 0
1 5
2 0
2 5
0 2 4 6 8 1 0 1 2
M i n i m u m V e r t i c a l R i s e
( f t )
M i n i m u m V e r t i c a l V e n t f o r T h r e e El b o w s
L e n g t h o f H o r i z o n t a l S e c t i o n s ( F T )
O N E 9 0 ° EL B O W
Total
H oriz ontal
M inimum
Vertical
Vent
Diameter
4 0 3
5 5 3
6 6 3
7 7 3
8 8 4
9 9 4
1 0 1 0 4
1 1 1 1 4
1 2 1 2 4
1 3 1 3 4
1 4 1 4 4
1 5 1 5 4
1 6 1 6 4
1 7 1 7 4
1 8 1 8 4
1 9 1 9 4
T W O 9 0 ° EL B O W S
Total
H oriz ontal
M inimum
Vertical
Vent
Diameter
2 5 3
36 3
4 7 3
5 8 3
6 9 3
7 1 0 4
8 1 1 4
9 1 2 4
1 0 1 3 4
1 1 1 4 4
1 2 1 5 4
1 3 1 6 4
1 4 1 7 4
1 5 1 8 4
T H R EE 9 0 ° EL B O W S
Total
H oriz ontal
M inimum
Vertical
Vent
Diameter
2 1 1 4
3 1 2 4
4 1 3 4
5 1 4 4
6 1 5 4
7 1 6 4
8 1 7 4
9 1 8 4
1 0 1 9 4
1 1 2 0 4
WARNING!
F i re R i sk.
• O n ly L I ST E D ven ti n g
compon en ts may b e
u sed
• N O O T H E R ven t compon en ts may b e u sed .
Su b sti tu te or d amag ed ven t compon en ts
may i mpai r saf e operati on .