Product Info
Table Of Contents
- Foreword
- 1 Overview
- 2 Description
- 3 Installation
- 4 Operation
- 5 Maintenance
- 6 Connector information
- 7 Specification
- 8 Associated equipment
- Index
- Annex
T6-D-USER-TRV-EN Page 5-2 Maintenance
© Park Air Systems Ltd 2016
5.2 Status message procedure
The table shows Status messages, message descriptions and necessary actions.
5.2.1 Radio Health
An internal radio failure is displayed on a suitable laptop (or desktop) and/or the RCMS, Park Air R4 MARC Server.
With access to the radio’s web server, the following Radio Health messages may be displayed:
If an internal radio failure clears, the radio health message clears.
On R4 MARC Server, Radio Health messages will be displayed in the BIT Status pane:
Status messages Description Action
AC Supply AC supply failed/disconnected
Measure the AC supply
Do a continuity test of the AC fuse
DC Supply
DC supply less than minimum DC
voltage level
Measure the DC supply
DC supply failed/disconnected
Measure the DC supply
Do a continuity test of the DC fuse
VSWR VSWR too high
Make sure the antenna circuit connections are correctly connected
Do a VSWR test of the antenna circuit
Ambient Temp Ambient temperature too high
Measure the local environment temperature
Make sure the cabinet cooling operates
Is the Fan status message shown?
System Active communication is lost Make sure that other system equipment is correctly connected
Amplifier External amplifier fault
Is the Error status shown on the external amplifier?
Make sure the RF and control connections to the external amplifier
are correctly connected
E-BIT External equipment failure
Make sure the antenna circuit connections are correctly connected
Is the Auto-tune filter defective?
Fan Internal fan failure Replace the internal fan, see 5.3 Fan replacement
Radio Health Integral radio failure See 5.2.1 Radio Health
Radio Health message Description
Degraded performance
An internal control system parameter may not be to
specification
Power removed
Transmit power has been automatically reduced to zero due
to one or more internal or external conditions
Not on frequency
An internal fault prevents the radio locking to the selected
frequency
Not calibrated Valid calibration data is not detected
Internal fault Detection of an internal fault