2-1
CALIBRATION PROCEDURE
1. Pan / Tilt Calibration
3 The Pan / Tilt Calibration is required in the fol-
lowing cases.
After replacing the EEPROM, Pan / Tilt and Zoom wheel
Calibration is required.
(Default software data will be stored in the EEPROM
automatically.)
In the case of changing of the combination of the Main
Unit and the 3D Joystick Unit as shown in the Exploded
View(10/10).
In the case of replacing of the Joystick Board (PCB 5) or
VR101 and other parts on it.
In case of replacing the Main Board (PCB 1) or EEPROM
(IC6 ) and other parts on it.
In case that calibrated data has been changed by opera-
tion mistake.
3 Procedure
1. Turn off the power.
2. To execute the Pan / Tilt Calibration Mode, Turn on the
power while pressing the [9] and [MON(ESC)] keys
simultaneously.
The LCD on the Front Panel will indicate as right.
3. Enter the administrator password.
Notes: • The factory default is "650".
To delete a character, press the CLEAR button.
Note: Just example, It depends on Unit
4. Press the [CAM(SET)] key.
The LCD on the Front Panel will indicate as right.
5. Press the [CAM(SET)] key for the starting adjustment.
The LCD on the Front Panel will indicate as right.
6. Turn and keep the Joystick to fully upper side.
The LCD on the Front Panel will indicate as right.
7. Press the [CAM(SET)] key while turning the Joystick to
upper side.
The LCD on the Front Panel will indicate as right.
8. Turn and keep the Joystick to fully down side.
The LCD on the Front Panel will indicate as right.
9. Press the [CAM(SET)] key while turning the Joystick to
down side.
The LCD on the Front Panel will indicate as right.
10. Return the Joystick to center.
The LCD on the Front Panel will indicate as right.
Note : It needs your hand to release with flipping.
11. Press the [CAM(SET)] key.
The LCD on the Front Panel will indicate as right.
12. Turn and keep the Joystick to fully right side.
The LCD on the Front Panel will indicate as right.
13. Press the [CAM(SET)] key while turning the Joystick to
right side.
The LCD on the Front Panel will indicate as right.
Pan/Tilt Calibration
Admin Password _____
U:F2 D:09 TC:78 0
R:E6 L:06 PC:75 0
U:__ D:__ TC:__ 72
R:__ L:__ PC:__
U:__ D:__ TC:__ F0
R:__ L:__ PC:__
U:F1 D:__ TC:__ 7D
R:__ L:__ PC:__
U:F1 D:__ TC:__ 08
R:__ L:__ PC:__
U:F1 D:08 TC:__ 08
R:__ L:__ PC:__
U:F1 D:08 TC:__ 70
R:__ L:__ PC:__
U:F1 D:08 TC:70 79
R:__ L:__ PC:__
U:F1 D:08 TC:70
R:__ L:__ PC:__ F1
U:F1 D:08 TC:70
R:F0 L:__ PC:__ F0
Blinking