Manual

13
English
[The images shown in this manual are for illustrative purpose only.]
Ceiling unit (1)
Bolt for fixing upper and lower sections (2)
M8 × 12
Spring washer (1)
M8
Clamper (2)
Dished toothed washer
(4)
Allen head countersunk
screw (4)
M8 × 32
Truss tapping screw (3)
Screw for securing unit (2)
M5 × 35
Allen wrench
(included tool) (1)
Washer pan nut (1)
M8
Insulation spacer (4)
Through bolt for fixing
upper and lower sections
(1) M8 × 100
Ceiling cover (1)
Rotation stop screw (1)
M6 × 8
Spring washer (1)
M6
Check that all the parts are accounted for and present in their designated quantities.
Precautions for ceiling-hanging bracket fitting
This equipment is a ceiling unit to suspend the Plasma Display from a ceiling structure for viewing purposes. The
ceiling unit must not be installed in any locations other than ceiling structures with sufficient strength.
To ensure correct plasma display performance and prevent trouble, do not fit at any of the following locations.
• Near sprinklers or fire/smoke detectors
• Where there is a risk of exposure to vibration or impact
• Near high-voltage wires or dynamic power supplies
• Near sources of magnetism, heat, water vapor or soot
• Locations exposed to air blown from heating equipment
• Where droplets of condensation from an air conditioner or other unit may form
Fit using techniques suited to the structure and materials of the fitting location.
When installing the ceiling unit to a ceiling structure, use structural components appropriate to the material of the
structure, and an installation method.
Ensure good air flow so that the ambient temperature does not exceed 40 °C (104 °F).
Failure to do this may cause heat to build up inside the plasma display, resulting in malfunction.
Spread a soft blanket or cloth over the floor so that the plasma display and floor will not be marked or scratched
during the assembly and installation work.
When screwing down the parts, ensure that the screws are neither insufficiently tightened nor over tightened.
Take sufficient care and ensure safety around you when performing the installation work.
Do not install the plasma display underneath ceiling lamps (spotlights, halogen lamps, etc.).
Otherwise, the cabinet may be bent or damaged by high heat.
Components