Dimensions Guide

Specication Submittal Data / Panasonic ERV
Description
Ceiling or wall mount Cold Climate Energy
Recovery Ventilator (ERV) provides a tempered
air supply, humidity control, and a balanced
amount of exhaust to help maintain balanced,
positive or negative pressure throughout the
home. Panasonic ERV is engineered for use
in any North America climate zone. Only one
unit is needed for a ≤ 3,000 sq. ft., up to 7
bedroom home to meet the ASHRAE 62.2
ventilation requirement. Built-in ASHRAE 62.2
Timing function helps ensure code compliance.
Motor/Blower:
• Two (2) enclosed DC brushless motors rated
for continuous run.
• ERV Supply and Exhaust ventilation rates
shall be manually adjustable for 50-60-70-80-
90-100 CFM.
• Power rating shall be 120 volts and 60 Hz.
• Motor equipped with thermal cut-off fuse
control.
• Removable, permanently lubricated, plug–in
motor.
Housing:
• 22 gauge galvanized steel body.
• Four 4" or 6" intake and exhaust ducts.
• Built in damper on Outdoor Air (OA) closes
during defrost function when the outdoor
temperature is too cold.
• Filters on supply and exhaust air extend the
life of the ERV core.
• (4) Pressure ports allow for easy airow
verication.
• Pre-drilled mounting bracket can
accommodate 16", 19", or 24" on center.
Maintenance:
• MERV 8 lter included; MERV 8 (FV-
FL0810VE1) and optional MERV 13 (FV-
FL1310VE1) replacements available.
• Unobtrusive alarm noties owner for lter
check and maintenance.
Warranty:
• DC Motors: 6 years from original purchase
date
• All Parts: 3 Years from original purchase date.
Architectural Specications:
ERV shall be ceiling or wall mount type with
built-in speed selectors for both Supply and
Exhaust air. Select from 50/60/70/80/100
CFM. ERV shall have 95 Net CFM on the
exhaust ports and 99 Net CFM on the supply
ports as tested in accordance with HVI 915
and 916 standards at 0.1 static pressure in
inches water gauge. ERV shall have 95 Net
CFM on the exhaust ports and Net 101 CFM
on the supply ports at 0.4" w.g. static pressure.
Power consumption shall be no greater
than 62 watts at 0.1" w.g. and 80 watts at
0.4" w.g. static pressure. Apparent Sensible
Effectiveness for heating shall be no less than
90% at 54 CFM net air ow under 32°F (0°C)
as tested in accordance with CSA-C439. Total
Recovery Effectiveness for cooling shall be no
less than 73% at 52 CFM net air ow under
95°F (35°C). The supply port damper shall
close when outdoor temperatures are < 14°F
(-10°C) to prevent freezing of the core. The (2)
motors shall be totally enclosed DC brushless
motors rated for continuous run. DC motor
speed shall automatically increase when the
fan senses static pressure to maintain selected
CFM. ERV shall incorporate an ASHRAE 62.2
Timing function for code compliance. Power
rating shall be 120v/60Hz. Duct diameters shall
be no less than 4". ERV can be used to comply
with ASHRAE 62.2, LEED, IAP, California
Title-24, and WA Ventilation Code.
ERV Core Technology:
• Indoor and outdoor air passes through
Panasonic’s capillary core technology. This
process tempers supply air while transferring
moisture and energy.
• Built in Frost Prevention Mode prevents the
core from freezing. Frost Prevention Mode
is free of interaction and operates without
intervention.
FV-10VE1
Temperate Climate ERV
Panasonic Eco Solutions North America
Eco Products Division
Two Riverfront Plaza
Newark, NJ 07102
us.panasonic.com/ventfans
For complete Installation Instructions visit us.panasonic.com/ventfans
Model Quantity Comments Project:
Location:
Architect:
Engineer:
Contractor:
Submitted by:
Date:
VF17024SS-10VE1
FV-10VE1
Four 4" or 6" ducts
Energy Recovery Ventilator
Optional Exterior Wall Cap (see next page)
DC Motor Technology
When the ERV senses static pressure, its
speed is automatically increased to ensure that
the desired CFM is not compromised, which
allows the ERV to perform as rated.
28-1/2
'
8-7/8'
23'
4' D ia
6' D ia
6' D ia
4' D ia
13'
B
E
S
T
E
N
E
R
G
Y
E
F
F
I
C
I
E
N
T
P
R
O
D
U
C
T
B
E
S
T
O
F
I
B
S
A
W
A
R
D
S
W
I
N
N
E
R

Summary of content (2 pages)