Panasonic SUPPLEMENTARY INSTALLATION INSTRUCTIONS Ventilating Fan (Contractor Pack) FY-07VBA1L FV-Q7VBEB1 READ AND SAVE THESE INSTRUCTIONS Thank you for purchasing this Panasonic product. CONTENTS Model No. FV-07VB1 GENERAL SAFETY INFORMATION «rover centennial 2-3 DESCRIPTION Housing Can: UNPACKING SUPPLIED ACCESSORIES DIMENSIONS WIRING DIAGRAM INSTALLATION FORFV-07VBAT (JOIST MOUNTING).
GENERAL SAFETY INFORMATION For Your Safety To reduce the risk of injury, loss of fe, electric shock, fire, malfunction, and damage to equipment or property always observe the following safety precautions.
GENERAL SAFETY INFORMATION CONTINUED A WARNING Canada only: Not to be installed in a ceiling thermally insulated to a value greater than R40. Do not disassemble the unit for reconstruction. It may cause fire or electric shock, When this product is no longer being operated, please remove the product to prevent the possibility of falling. Ceiling joist must be subjected to static load more than five times the weight of the product. Do not install with a method which is not approved in the instructions.
DESCRIPTION The Panasonic ventilating fan model is listed by UL under UL file No. E78414. The Panasonic ventilating fan model uses a sirocco Blower driven by a capacitor motor. The motor is designed to have an extended service life with reduced energy consumption. it also incorporates a thermal cutoff for safety.
WIRING DIAGRAM Fan Body Junction Box Ri Capacitor White [White 3 {134% Fuse in motor) Switch Power supply Motor | Thermally pi Yellow! || wavelike [F Standard ACACIA 60Hz Black lenitive Black Black > (each oy in motor) H-Boost carnally port INSTALLATION FOR FV-07VBA1 (oi St Mou HL 1. Before installation, use Flathead screwdriver to knock put the two screw holes on the side of the Fan Housing that will ba fixed to the Joist. (Fig.1} 2.
INSTALLATION FOR FV-07VBA1 CONTINUED 10. Affix the Junction Box to the top of the Fan Housing with Screw | (ST4.2X8). {Fig.5) A CAUTION 0 Before affixing the screw make sure the Tongue of the Junction Box is clipped on Fan Housing correctly. {Fig.4 of page 5) Aunt Junction Box Cover carefully so that head wires are not pinched. 11. Select the air volume speed by adjusting the Switch, Factory setting is “1” (Standard) position; pressing “If” (Boost) selects the high airflow position. {Fig.5) 12.
INSTALLATION FOR FV-07VBB1 CONTINUED 3. insert the Grille Assembly Mounting springs into the Slots as shown and mount Grille Assembly to Fan oun taunting Body. {Fig.9) spring Lowe | Grille Assembly Fig.s MAINTENANCE (CLEANING) Slot A WARNING an spring Oo Disconnect power source before working on unit. A CAUTION Oo Routine maintenance must be done every year. Never use gasoline, benzene, thinner or any other such chemicals for dealing the ventilating fan. Do not immerse motor in water when cleaning.
PRACTICAL GUIDE TO INSTALLATION Properly insulate the area around the fan to minimize building heat loss and gain, {Fig.14) Four inch roof jack, wall cap, or offsite vent with backtrack damper... 3 mechanically concert duct to termination ard seal with mastic or approved foil faced tape ~ -3 fe straight run before elbow In attic installation, caulk box 10 drywall Loose fill or bat insulation can be placed directly over the fan housing in the attic.