User Guide

Before proceeding with installation, be sure to read and completely
understand all safety and warning information in the “GENERAL
SAFETY INFORMATION” section of the instruction manual.
Quick Start Installation Guide (Retrofit)
Install the circular exhaust duct and secure it with
clamps, or tires and seal it with mastic or approved foil
tape. A 3 of 4 inch circular duct is needed to connect to
the relevant part of adaptor.
Remove screw with junction box cover and secure conduit
or stress relief to junction box knock-out hole.
Remove the existing fan and use housing masking
template to mark the ceiling opening and cut the
ceiling along the marking line.
2
1
Install bracket to joist using 2-preinstalled tapping screws.
Flex-Z Fast
TM
bracket
10 7/8
(275)
10 7/8
(275)
2
2
1
3
4
The Flex-Z Fast bracket position can be adjusted exibly between joists from 16" to 24".
Install Flex-Z Fast bracket
TM
TM
Connecting wires
Install circular exhaust duct
Refer to WIRING DIAGRAM.
Follow all the local electrical safety codes as well as the
National Electrical Code (NEC). Using UL approved wire
nuts to ventilating fan wires. After connecting wires screw
back junction cover.
1
Joist
5
6
Extend bracket to the other joist.
Install bracket to joist using 2-preinstalled tapping screws.
5
6
A
2 Tapping
screws
(ST4.2X20)
Please remove the tape
placed on the damper
and adaptor before
installation.
Tape
Adaptor
Damper
[ FV-0511VFC1 ]
1
Two red wires (Connect to a
general manual wall switch)
Earth ground
Conduit
Earth
ground
Live (Fan)
Switch box
Neutral
[ FV-0511VF1 ]
1
Earth ground
Conduit
Earth
ground
Live (Fan)
Neutral
Extend
Bend down 4 tabs and align bracket to the joist.
A
Joist
Bend down
4 tabs
3
4
2 Tapping screws
(ST4.2X20)
TM
Flex-Z Fast
bracket
Align
Flex-Z Fast
TM
bracket
Circular
exhaust duct
Conduit
Junction
box cover
1
2
Joist
Adaptor
Insert the Flex-Z Fastbracket into the opening and extend.
Unit: inches (mm)
1
Secure the fan body to Flex-Z Fast™ bracket by using 2
self-drilling screws.
Plug connector to receptacle and secure the fan body to
adaptor by using machine screw (M4X8).
1
2
Self-drilling screw
Drywall
1
Install the adaptor to Flex-Z Fast™ bracket by using
2 self-drilling screws.
1
Install adaptor
Insert fan body and slide into adaptor assembly using
the guide parts until you hear a click from the hook.
1
Insert fan body
2
Secure fan body
Grille
Drywall
Gloves
Mounting spring
After nishing the ceiling job, ll gap between
ange and ceiling with caulk or other sealant to
prevent air leakage.
Insert the mounting springs into the slot as shown
and mount grille to fan body.
1
Adjust Pick-A-Flow switch.
2
1
1
1
Install grille
Sealing
2 Self-drilling screws
Circular
exhaust duct
Conduit
1
A
Flange
2 Self-drilling screws (x the
ange and Flex-Z Fast bracket
through the drywall)
TM
Drywall
Joist
Plug
connector
Receptacle
Machine screw (M4X8)
1
Guide
parts
Guide
parts
1
Fan body
FV-0511VFC1
DC
motor
Condensation sensor
Main
control
circuit
Black
Control switch
White
Red
Red
Green
Junction box
Power switch
Live (Fan)
Neutral
(Ground wire)
Power supply
AC 120 V 60 Hz
Do not connect the red signal wires to a live
power supply (AC 120V 60 Hz), it will
damage the product. Please use an optional
switch to connect the red signal wires.
Fan body
Main control circuit
Main control circuit
DC
motor
Main
control
circuit
Black
White
Green
Junction box
Power switch
Live (Fan)
Neutral
(Ground wire)
AC 120 V 60 Hz
(Power supply)
FV-0511VF1
Grille
Self-drilling
screw
Installation
instructions
Warranty
sheet
Machine
screw
(M4X8)
Quick
Start
Guide
3 inch adaptor
connector
(optional part)
Part name Appearance Quantity Part name Appearance Quantity
TM
Flex-Z Fast
bracket
(with 4
tapping screws
-ST4.2X20)
SUPPLIED ACCESSORIES
English

Summary of content (1 pages)