Panasonic Supplementary Installation Instructions Ventilating Fan (Contractor Pack) Housing can FV-0510VSA1 Motor/Grille assembly FV-0510VSB1 Applicable to Model: F-0510vS1 Model No.
GENERAL SAFETY INFORMATION For Your Safety To reduce the risk of injury, loss of life, electric shock, fire, malfunction, and damage to equipment or property, always observe the following safety precautions. Explanation of symbol word panels The following symbol word panels are used to classify and describe the level of hazard, injury, and property damage caused when the denotation is disregarded and improper use Is performed.
GENERAL SAFETY INFORMATION A WARNING 0 This model is UL listed for tub and shower enclosures. 0 A statement to the effect that when the product is to no longer be used, it must not be left in place but remove, to prevent it from possibly falling. 0 Ceiling joist or wall stud must be subjected to static load more than five times the weight of the product. Install the fan at least 1.5 m feet) above the floor, and the fan must be installed above a counter or major appliances that serves as a barrier.
GENERAL SAFETY INFORMATION NOTICE Provide make up air for proper ventilation. © When one switch is connected with two or more products in parallel, the unit may not function. Therefore, parallel connection must not be allowed. © Do not install the unit where ducts are configured as shown in below. 7 up —— vapor Ry Excessive bending Successive bending Squeezed duct Bend close to duct adapter DESCRIPTION This product is listed by UL under UL file No. E78414.
FEATURE This product employs innovative, state-of-the-art technologies that provide a number of customization unique features that lead to improved indoor air quality. Please read this manual first in order to realize the benefits of this customization, modular fan. Optimum Ventilation Performance: Duct length, elbows and other factors increase static pressure which can hinder the performance of most ventilation fans.
INSTALLATION I (JOIST MOUNTING) 3.Remove junction box cover and secure conduit or stress relief to junction box knock-out hole. {Fig.3) 4.Refer to wiring diagram follow all the local electrical safety codes as well as the National Electrical Code (NECK. Using UL approved wire nuts, connect house wore wires to ventilating fan wires. Fig.3) A CAUTION Mount junction box cover carefully so that lead wires are not pinched. 5.A 4 inch circular duct is needed to connect to the relevant part of adapter.
INSTALLATION I (JOIST MOUNTING) 9.Take out the mounting springs of grille fn As 0VSB1 packing case) from clips. Fig.7 10.Insert the mounting springs into slots as shown and mount grille to fan body. (Fig.8) Fig.8 INSTALLATION II (WALL MOUNTING) 1.Before installation, please refer to step 1 of INSTALLATION 1. (P.5} 2.Fix the flange of frame to stud by 2 long screws (ST4.2X30), and fix the suspension bracket to stud by 2 long screws (ST4.2X30). (Fig.
MAINTENANCE (CLEANING) A WARNING 0 Disconnect power source before working on unit. A CAUTION Routine maintenance must be done every year. Please wear gloves during the cleaning work. Fig.11 Do not immerse motor in water when cleaning. NOTICE Do not soak resin parts in water over 140 °F (60 °C). Never use gasoline, benzene, thinner or any other such chemicals for cleaning the ventilating fan. 1.Remove grille. (Squeeze mounting spring and pull down carefully) {Fig.11) 2.Wash and clean grille.