Datasheet

DK
1
ds_61A03_en_dk: 070313D
ORDERING INFORMATION
1a 10 A,1a1b/2a 8 A small
polarized power relays
DK RELAYS
VDE
FEATURES
1. Compact with high capacity
High capacity switching in a small
package: 1 Form A, 10 A 250 V AC;
1 Form A 1 Form B and 2 Form A, 8 A
250 V AC.
2. High sensitivity: 200 mW nominal
operating power
3. High breakdown voltage
Independent coil and the contact
structure improves breakdown voltage.
Conforms with FCC Part 68
4. Latching types available
5. Sealed construction allows
automatic washing.
6. High insulation resistance
Creepage distance and clearances
between contact and coil: Min. 8 mm
DK2a-L2: 6.8 mm
DK1a1b-L2: 6.8 mm
7. Sockets are available
8. Complies with safety standards
Complies with Japan Electrical
Appliance and Material Safety Law
requirements for operating 200 V
power supply circuits, and complies
with UL, CSA, and TÜV safety
standards.
TYPICAL APPLICATIONS
1. Switching power supply
2. Power switching for various
OA equipment
3. Control or driving relays for
industrial machines (robotics,
numerical control machines, etc.)
4. Output relays for programmable
logic controllers, temperature
controllers, timers and so on.
5. Home appliances
About Cd-free contacts
We have introduced Cadmium free type
products to reduce Environmental
Hazardous Substances.
(The suffix “F” should be added to the
part number)
(Note: The Suffix “F” is required only for
1 Form A contact type. The 2 Form A and
1 Form A 1 Form B contact type is
originally Cadmium free, the suffix “F” is
not required.)
Please replace parts containing
Cadmium with Cadmium-free products
and evaluate them with your actual
application before use because the life of
a relay depends on the contact material
and load.
Between contact
and coil
Between open contacts
4,000 Vrms for 1 min.
10,000 V surge
breakdown voltage
1,000 Vrms for 1 min.
1,500 V surge
breakdown voltage
Coil voltage (DC)
3, 5, 6, 9, 12, 24V
DK
Operating function
Nil:
L:
L2:
Single side stable
1 coil latching
2 coil latching
Contact arrangement
1a:
2a:
1a1b:
1 Form A
2 Form A
1 Form A 1 Form B
Notes: 1. UL/CSA, TÜV approved type is standard.
2. VDE approved type is available.
Contact material
F:
Nil:
1 Form A (AgSnO2 type)
2 Form A, 1 Form A 1 Form B (Au-flashed AgNi type)