Panasonic WhisperControl Submittal
Condensation Sensor Plus – Fan Only
• Combination humidity and temperature sensor anticipates dew point, automatically turning the fan on.
• Adjustable Minutes Per Hour fan timer (0-60 mins) for compliance with ASHRAE 62.2.
• Moisture Sensitivity Selector allows ne tuning for dry or moist environments.
• Automatic Fan Control - 30 minute countdown timer initiates after moisture returns to normal levels.
• Manual Fan Control - 20 minute countdown timer initiates once fan is turned on.
• Blue LED indicates when the fan is on.
• Commercial Grade - 8 Amp max load, 2 year
limited warranty*.
• For indoor use. Includes matching wall plate.
• May be used to comply with ASHRAE 62.2,
LEED, ENERGY STAR
®
3.0 and CALGreen.
FV-WCCS1-W (White)
FV-WCCS1-A (Light Almond)
FV-WCCS2-W (White)
FV-WCCS2-A (Light Almond)
Product Specications
Ground Grounding
Feature Blue LED When On
Amperage 15
Maximum Fan Load 8 Amps
Voltage 120 Volts
Dry Contact Switching 24 Volt AC Input/Output
Terminations 6" Leads
Connections (Copper Wire Connections) Use #14 or #12
Max Fluorescent Light Load N/A
Standards and Classications UL/CSA Listed
Warranty 2 Year Limited
Specication Submittal Data
WhisperControl
Panasonic Eco Solutions North America
Eco Products Divsion
Two Riverfront Plaza
Newark, NJ 07102
us.panasonic.com/ventfans
Condensation Sensor Plus – Fan/Light
• Combination humidity and temperature sensor anticipates dew point, automatically turning the fan on.
• Adjustable Minutes Per Hour fan timer (0-60 mins) for compliance with ASHRAE 62.2.
• Moisture Sensitivity Selector allows ne tuning for dry or moist environments.
• Automatic Fan Control - 30 minute countdown timer initiates after moisture returns to normal levels.
• Manual On/Off Fan Control - 20 minute countdown timer initiates once fan is turned on.
• Manual On/Off Light control.
• Blue LED indicates when the fan is on.
• Commercial Grade - 8 Amp max load, 2 year
limited warranty*.
• For indoor use. Includes matching wall plate.
• May be used to comply with ASHRAE 62.2,
LEED, ENERGY STAR
®
3.0 and CALGreen.
Product Specications
Ground Grounding
Feature Blue LED When On
Amperage 15
Maximum Fan Load 8 Amps
Voltage 120 Volts
Dry Contact Switching 24 Volt AC Input/Output
Terminations 6" Leads
Connections (Copper Wire Connections) Use #14 or #12
Max Fluorescent Light Load 400 Watt
Standards and Classications UL/CSA Listed
Warranty 2 Year Limited
* One year additional fan warranty available when a Panasonic WhisperCeiling/Lite, WhisperValue
or WhisperFit/Lite fan is controlled by the Panasonic Condensation Sensor Plus.
For complete Installation Instructions visit
us.panasonic.com/ventfans
* One year additional fan warranty available when a Panasonic WhisperCeiling/Lite, WhisperValue
or WhisperFit/Lite fan is controlled by the Panasonic Condensation Sensor Plus.
On/Off
FV-WCCS1-W (White)
FV-WCCS1-A (Light Almond)
Timer and Sensor Settings:
Minutes Per Hour (MPH) fan
timer (left) and Moisture
Sensitivity Selector (right),
hidden behind a removable
cover.
Minutes Per Hour (MPH) Fan Timer:
Runs fan for a selected amount of time every hour, (0-60 mins.) for
compliance with ASHRAE 62.2. For example, set to "0", the MPH timer
will never turn on. Set to "10", the MPH timer will turn the fan on 10
minutes every hour. Set to "60", the MPH timer will run the fan all the
time. The MPH fan timer will also credit any manual use time to the next
hours operation (up to 3 hours ahead).
Moisture Sensitivity Selector: Adjusts the unit's sensitivity based
on regional climate, size of bathroom and preferred dryness level.
Choose from High, Average or Low sensitivity.
Fan ON/OFF: Turns 20-minute countdown timer ON and OFF (can
be used to temporarily override the Condensation Sensor Plus).
High Sensitivity - Most sensitive setting, for dryer climates
and/or larger rooms.
Average Sensitivity Sensitivity - Condensation Sensor
Plus comes factory set to this most common setting.
Low Sensitivity - Least sensitive setting, used in hotter
and more humid climates.
Timer and Sensor Settings:
Minutes Per Hour (MPH) fan
timer (left) and Moisture
Sensitivity Selector (right),
hidden behind a removable
cover.
Minutes Per Hour (MPH) Fan Timer:
Runs fan for a selected amount of time every hour, (0-60 mins.) for
compliance with ASHRAE 62.2. For example, set to "0", the MPH timer
will never turn on. Set to "10", the MPH timer will turn the fan on 10
minutes every hour. Set to "60", the MPH timer will run the fan all the
time. The MPH fan timer will also credit any manual use time to the next
hours operation (up to 3 hours ahead).
Moisture Sensitivity Selector: Adjusts the unit's sensitivity based
on regional climate, size of bathroom and preferred dryness level.
Choose from High, Average or Low sensitivity.
Fan ON/OFF: Turns 20-minute countdown timer ON and OFF (can
be used to temporarily override the Condensation Sensor Plus).
On/Off
FV-WCCS2-W (White)
FV-WCCS2-A (Light Almond)
High Sensitivity - Most sensitive setting, for dryer climates
and/or larger rooms.
Average Sensitivity Sensitivity - Condensation Sensor
Plus comes factory set to this most common setting.
Low Sensitivity - Least sensitive setting, used in hotter
and more humid climates.