EN Full Weather Station with Radio Controlled Clock and Projection (Model #: PS-L02 / PS-L02U) User Manual PS-L02_GB-final.
EN PS-L02_GB-final.
EN Projector ................................................................. 18 Reset system ........................................................... 19 Safety and care ....................................................... 20 Warnings ................................................................. 20 Troubleshooting ....................................................... 21 Specifications .......................................................... 22 Additional resources ...........................
EN In this box, you will find: ABOUT THIS GUIDE Congratulations on your selection of the Philippe Starck with Oregon Scientific Full Weather Station with Radio Controlled Clock and Projection (PS-L02 / PS-L02U). This powerful device bundles time keeping, alarm, indoor and wireless outdoor temperature and humidity monitoring, weather forecasting, and projection features into a single tool you can use from the convenience of your home.
EN PRODUCT OVERVIEW DESCRIPTIONS TOP VIEW 1. 2. 3. Snooze / Light button (→ 12, 17, 18, 19) Light sensor (→ 17) Projection lens (→ 18) 1 2 3 3 PS-L02_GB-final.
EN LCD DISPLAY DESCRIPTIONS 1. 2. 3. 4. 5. 6. 7. 8. 1 2 3 7 Low batteries icon (→ 8) Clock (→ 10) Barometer (→ 13) Weather forecast (→ 14) Moon phase (→ 12) Calendar (→ 12) Temperature and humidity (→ 14) Alarm (→ 11) 4 8 5 6 4 PS-L02_GB-final.
EN BACK VIEW BUTTON DESCRIPTIONS 1. 2. 3. 4. 5. 1 2 3 4 6. 7. Focus – focus projector (→ 19) Select – switch modes / change settings Rotation – rotate projector (→ 19) Up – increase setting / activate auto-synch (→ 11) Down – decrease setting / deactivate auto-synch (→ 11) Alarm –activate / deactivate alarm (→ 11) Channel – switch remote unit (→ 15) 5 6 7 5 PS-L02_GB-final.
EN BOTTOM VIEW DESCRIPTIONS 1. 2. 3. 4. 5. 1 2 3 Battery compartment (→ 8) Light sensitivity knob (→ 18) Reset button (→ 8, 19) Backlight switch (→ 17) DC power input jack (→ 8) 4 5 NOTE AC power adapter not shown. 6 PS-L02_GB-final.
EN REMOTE UNIT DESCRIPTIONS 1 1. 2. 3. 4. 5. 6. 7. 8. 9. 4 5 6 2 7 3 Temperature / Trend display Low battery icon Humidity / Trend / Comfort Level display °C / °F switches Channel switches Reset button Battery compartment Wall-mount hole Battery compartment lid 8 9 7 PS-L02_GB-final.
EN GETTING STARTED NOTE Insert the batteries in the remote unit before you set up the main unit. Do not use rechargeable batteries. BATTERIES Batteries for the remote and main units are supplied with this product. Replace them whenever the low battery signal ( ) displays. Remove the battery compartment lid on the bottom of the main unit, and insert the batteries. Use a small Phillips screwdriver to remove the remote unit compartment lid.
EN SWITCH BETWEEN MODES Press SELECT. The select mode will flash. The display will stop flashing if no key is pressed within 5 seconds. NOTE Additional remote units sold separately. If you are using more than one remote unit, be sure to select a different channel number for each unit. CHANGE SETTINGS Press and hold SELECT for 2 seconds. Then, press UP or DOWN to change each setting. Press SELECT to switch options.
EN • Position the unit so that it faces the main (indoor) unit. Minimize obstructions such as doors, walls, and furniture. RECEPTION Reception takes 2 – 10 minutes to complete. Once complete, the icon will stop blinking. You may need to experiment with various locations to get the best reception. Strong signal CLOCK This product can automatically synchronize the date and time with official time-keeping organizations in Frankfurt, Germany (PS-L02) or Rugby, England (PS-L02U).
EN TO DISABLE OR ENABLE AUTOSYNCHRONIZATION In Clock mode, press DOWN for 2 seconds to disable the auto-synchronization. The unit will not respond to radio signals until you reactivate the synchronization. ALARM When activated, the Melody Alarm starts quietly, then gradually becomes louder. It shuts off after two minutes. The LCD display lights up for the first 8 seconds. SET ALARM To enable auto-reception, press UP for 2 seconds. 1. SET OR CHANGE THE CLOCK 1. 2. 3. 2.
EN SNOOZE Press the SNOOZE/LIGHT button the top of the unit to temporarily disable the alarm for 8 minutes. The alarm icon will blink while Snooze is activated. 1. 2. 3. TO TURN THE ALARM OFF OR ON Press any button to stop the alarm. To turn the alarm off completely (deactivate it for the next day), press ALARM. Press SELECT several times until the calendar area flashes. Press and hold SELECT for 2 seconds to enter the calendar setting mode. Select the year, month, date, and language.
EN BAROMETER This product tracks barometric pressure changes over the past 24 hours to provide the weather forecast (→ 14) and a trend line showing the direction of barometric change. Barometric changes are measured by the main (indoor) unit. Trend BAROMETRIC TREND The barometric trend arrow for the last 30 minutes is always displayed.
EN SET UNIT AND ALTITUDE You can set the unit of measurement (mb/hPa or inHg) and altitude. Setting the altitude allows the product to take more accurate barometric measurements. 1. 2. 3. WEATHER FORECAST This product forecasts the next 12 to 24 hours of weather within a 30 to 50 km (19 - 31 mile) radius with 70 to 75 percent accuracy. The weather forecast is always displayed. Press SELECT 2 times until the Barometer Area flashes. Press and hold SELECT for 2 seconds.
EN Outdoor measurements are collected by the remote unit. SELECT REMOTE UNIT CHANNEL While in the Temperature / Humidity Mode, press CHANNEL to switch between CH 1, 2, or 3, or press and hold CHANNEL for 2 seconds to enter Auto scan mode. If only 1 remote unit is in use, you will not be able to change channels or Auto scan. If you select “Auto”, the channel will change every 3 seconds. To deactivate, press and hold CHANNEL for 2 seconds again. Temperature is give at the top; humidity is below.
EN Searching No sensor COMFORT ZONE The indoor and outdoor comfort zones are shown for the following conditions. Sensor found Zone NOTE Signals from household electrical appliances such as doorbells and home security systems can cause temporary reception failures between the indoor and outdoor units. This is normal and does not affect the general performance of the product. Reception will automatically resume once the interference ends.
EN TRENDS The trend arrow for the last 30 minutes always displays. Indoor and outdoor temperature and humidity trends are shown separately. Trend Temperature Relative Humidity +0.5 °C +3% Steady Steady -0.5 °C -3% SET UNIT While in Temperature / Humidity Mode, press SELECT for 2 seconds. Press UP or DOWN to switch between °C and °F. Press SELECT to confirm. BACKLIGHT Press SNOOZE/LIGHT to illuminate the backlight for 5 seconds.
EN 2. 3. Move it to the “AUTO” position to enable continuous backlight controlled by light intensity. When activated, the backlight will be on whenever the unit perceives that the room is dark. The Light Sensitivity knob is located in the battery compartment. Rotate to adjust. PROJECTOR This product has a built-in projector for viewing time and alarm status at night. NOTE The maximum projection range is 2 meters (6 feet). The image gets larger the farther you display it.
EN ROTATE IMAGE The ROTATION switch is located on the back of the unit. Rotate to adjust. Press and hold SNOOZE/LIGHT for 2 seconds again to deactivate. RESET SYSTEM The RESET buttons are located in the battery compartments for the main and remote units. Press these buttons with the tip of a blunt object (such as a ball point pen) whenever you change the batteries, or whenever performance is not behaving as expected (e.g., unable to establish radio frequency link with remote unit or automatic clock, etc.
EN • SAFETY AND CARE Wash the unit with a slightly damp cloth and mild detergent. Avoid dropping the unit or placing it in a location where the AC power adapter will be stepped on. • • Do not use rechargeable batteries with this product. Remove the batteries if storing this product for a long period of time. Do not scratch the LCD display. • WARNINGS This product is designed to give you years of service if handled properly.
EN TROUBLESHOOTING Check here before contacting our customer service department. Problem Symptom Remedy Temp Shows “LLL” or “HHH” Temperature is out-ofrange. Calendar Strange date / month Change language (→ 12) Backlight No continuous backlight Plug in AC power adapter. Check the BACKLIGHT switch.
EN Problem Symptom Remedy SPECIFICATIONS 3. Replace batteries. 4. Place clock near window / away from electrical devices, and wait 10 – 20 minutes. Main unit dimensions LxWxH 181 x 45 x 185.3 mm (7.1 x 1.77 x 7.3 inches) Weight 914 grams with battery Remote unit dimensions LxWxH 75 x 35 x 78.3mm (3 x 1.4 x 3.1 inches) Weight 136 grams with battery If it still fails, you may be too far from a signal.
EN Temperature Unit Range Resolution Comfort Memory Trend Memory Trend °C or °F Main unit: -5 ˚C to 50 ˚C (23 ˚F to 122 ˚F) Remote Unit: -20 ˚C to 60 ˚C (-4 ˚F to 140 ˚F) 0.1 °C (0.2° F) 20 °C to 25 °C (68 °F to 77 °F) (see also, Relative humidity) Minimum / maximum +/- 0.5 ˚C (+/- 0.
EN Remote unit RF frequency Range Transmission Channel No.
EN ADDITIONAL RESOURCES Visit our website (www.oregonscientific.com) to learn more about your new product and other Oregon Scientific products such as digital cameras, hand-held organizers, health and fitness gear, and weather stations. The website also includes contact information for our customer service department, in case you need to reach us. 25 PS-L02_GB-final.
EN EC-DECLARATION OF CONFORMITY This product contains the approved transmitter module TX 07 and complies with the essential requirements of Article 3 of the R&TTE 1999/5/EC Directives, if used for its intended use and that the following standard(s) has/have been applied: Additional information: The product is therefore conform with the Low Voltage Directive 73/23/EC, the EMC Directive 89/336/EC and R&TTE Directive 1999/5/EC (appendix II) and carries the respective CE marking.