INSTALLATION INSTRUCTIONS IMPORTANT Keep appliance area clear and free from combustible materials,gasoline,and other flammable vapors. Gas Supply Requirements Installation of this range must conform with local codes,or in the absence of local codes, the National Fuel Gas Code, ANSI Z223.1 / NFPA 54. In Canada,installation must conform to the current natural Gas Installation /code,CAN 1-1.1-M81 and with local codes where applicable.This range has been design-certified according to ANSI Z21.12016/CSA 21.
INSTALLATION INSTRUCTIONS Dimensions and Clearances The range may be installed flush to the rear wall. You may install a noncombustible material on the rear wall above the range and up to the vent hood. It is not necessary to install non-combustible materials behind the range below the counter top height. The minimum distance from the side of the range above the counter top to combustible sidewalls must be at least 10 inches.
11
27 3 4〃 48〃 〃 Height 39 4 5〃 depth with door open 44 1 4〃 12
Dimensions and Clearances INSTALLATION INSTRUCTIONS The maximum depth of cabinets installed above cooking tops be 13 in(330mm) or a great specified by the manufactures as tested by the certification agency.
Electric Power Supply Requirements Your range must be electrically grounded in accordance with local codes or,in the absence of local codes,in accordance with the National Electrical Code (ANSI/NFPA 70, latest edition).In Canada, electrical grounding must be in accordance with the current CSA C22.1 Canadian Electrical Code Part 1 and/or local codes.A copy of this standard may be obtained from:National Fire Protection Association,1 Batterymarch Park,Quincy,Massachusetts 02269-9101.
Electrical Grounding Instructions:this indoor gas cooking appliance is equipped with a three-prong (grounding) plug for your protection against shock hazard and should be plugged directly into a properly grounded three-pronged receptacle. Do Not cut or removes the grounding prong from the plug. Caution Label all wires prior to disconnection when servicing controls. Wiring errors can cause improper and dangerous operation.Verify proper operation after servicing.
INSTALLATION INSTRUCTIONS Grounding • • • The power cord is equipped with a three-prong (grounding) plug which mates with a standard three-prong grounding wall receptacle to minimize the possibility of electrical shock hazard from the range. All cord connected appliance shall include instructions relative to location of the wall receptacle and a warning to the user to disconnect the electrical supply before serving the appliance.
Hood/Composite Overlay Install The bottom of the hood should be 30′′ min. to 36′′ above the counter top.This would typically result in the bottom of the hood being 66′′ to 72′′ above the floor. These dimensions provide safe and efficient operation of the hood. After Installation: Check ignition of cooktop burners. Check the air shutter adjustment – sharp blue flame,with no yellow tipping or lifting flames. Check ignition of oven burner.