Spec Sheet

REFERENCE QTY. REMARKS Project
Location
Architect
Engineer
Contractor
Submitted by Date
Broan-NuTone LLC Hartford, Wisconsin www.broan-nutone.com 800-558-1711
Venmar Ventilation ULC Drummondville (Quebec) www.nutone.ca 877-896-1119
SPECIFICATION SHEET
02J 1103129B
MODEL AERN110KA
ROOMSIDE SERIES FAN
KIT WITH SPEED CONTROL
DESCRIPTION
BLOWER:
Plug-in, permanently lubricated motor - engineered for continuous
operation
Dynamically balanced centrifugal blower wheel for quiet, efficient
performance
Low RPM for quiet operation
HOUSING:
Rugged, 26 gauge, galvanized steel construction
Polymeric, 4” duct connector with tapered sleeve and no metallic
clatter
5-3/4” height allows for 2” x 6” ceiling installations
Sturdy, easy, four-point mounting directly to joist
Can be mounted in ceilings up to 7/12 pitch
Can be installed in a wall if mounted 8-ft. or more above the floor
GRILLE:
Polymeric construction
Innovative design - the result of extensive research with designers
and consumers
• CleanCover
TM
grille stays cleaner longer with fewer vent slots to
collect dust
• CleanCover
TM
grille provides sleek, streamlined design to match any
modern décor
CONTROL (included):
Fits single-gang box
120 VAC, 3 Amp Max.
Operating temperature: 32-122°F (0-50°C)
Provides the ability to control CFM and sone levels to match any
bathroom application
Refer to NuTone’s catalog for a complete line of accessories to
effectively adapt these fans to your construction requirements.
U.L. Listed for use over bathtubs and showers when connected to a
GFCI protected branch circuit (ceiling mount only).
3-Year Warranty
TYPICAL SPECIFICATION
Fan kit shall be NuTone model AERN110KA, which includes
NuTone fan model AERN110K and Broan-NuTone speed control
model SC100W.
Fan shall be ENERGY STAR
®
certified.
Fan shall have corrosion resistant galvanized steel housing with
four-point mounting capability. It shall be ducted to a roof or wall
cap using 4” round ductwork.
Blower assembly shall be removable, have a centrifugal-type
blower wheel and a permanently lubricated motor designed for
continuous operation.
Non-metallic damper/duct connector shall be included.
Wall control rated for 3 amps, 120 VAC shall be included.
Wall control shall allow fan to be adjusted anywhere from 20 to
110 CFM, and from <0.3 sone to 1.0 sone.
All air and sound ratings shall be certified by HVI.
Fan shall be U.L. Listed for use over bathtubs and showers when
connected to a GFCI protected branch circuit.

Summary of content (4 pages)