Copyright All rights to these operating instructions are reserved. These operating instructions, including extracts thereof, must not be copied or translated into other languages without our written permission. Safety Instructions and Warnings Please read these instructions before installing and starting up the pressure switch. Failure to follow the instructions will make all guarantee, warranty and compensation claims null and void. connection, and the correct tools must always be used.
Exclusion of Liability NOSHOK guarantees that the pressure switch is in perfect working condition when it is delivered. The basis consists of the technical data in the data sheet and these operating instructions. Liability cannot be accepted for the suitability of the pressure switch. Temperature Switch Description The temperature switch has one analog output and one switching output or two switching outputs.
Round Connector M 12 x 1 (4-pin) Signal Connector Colors of Optional Wires Supply: + 1 brown Supply: - 3 blue Switch output S 1 4 black Switch output S 2 or analog output 2 white Recommended accessories: M12x1 socket with 2m cable • straight version, order no.: FS-2-4P • angled version, order no.
Switching On and Off The temperature switch is switched on when the supply voltage is applied. There is no on/off switch. A brief initialization phase occurs when the supply voltage is applied to the switch. The display and the set point LED illuminate. The measuring range (min- and max. temperature) and the unit are indicated briefly. The outputs are inactive during this time. After initialization the switch is in normal operating mode.
Parameter description / programming With two switching outputs Temperature units Degree Celsius Degree Fahrenheit Switch 1, Set Point Select set point for first switch Switch 1, Reset Point Select reset point for first switch Contact 1 Select contact function for first switch normally open Select normally open contact normally closed Select normally closed contact Switch 2, Set Point Select set point for second switch Switch 2, Reset Point Select reset point for second switch Contact 2 Select
6
With one switching output and one analog output Temperature units Degree Celsius Degree Fahrenheit Switch 1, Set Point Select set point for first switch Switch 2, Reset Point Select reset point for first switch Contact 1 Select contact function for first switch Normally open Select normally open contact Normally closed Select normally closed contact Current high Select temperature value for 20mA Current low Select temperature value for 4mA Store The previous changes are only accepted if butto
8
Technical data Temperature Ranges -58 to +392°F -58 to +752°F -58 to +1112°F -328 to +1112°F Measurement Units °C or °F (selectable) Sensor PT100 class B or PT100 class A Supply Voltage 12...30 Vdc, overload and reverse polarity protection ripple <10% Power Consumption ≤ 50mA, without load current Process Connections • Fixed Thread • Compression Fitting Materials • Process Connection • Housing 1/2NPT, 1/4NPT 1/2NPT Other connections on request Stainless steel 1.
Switching outputs • Switching function • Switching rating • Adjustment - Set Point - Reset point Analog output Signal adjustable normally closed (NC) or normally open (NO) contact 100mA per switching output Programmable via the display 0.1° steps withhin temperature range 0.1° steps from beginning temperature range until max. set point –0.1° 4…20mA; 2-wire, programmable in 0.
DIMENSIONS Inches (mm) 11
CE – Conformity The switch complies with all requirements of EN 61 326 with regard to interference emission and immunity for use in industrial areas. NOSHOK recommends the use of shielded cables. Installation and cable routing must be carried out correctly in order to maintain the effective protection from electromagnetic interference. Maintenance The temperature switches that are described in this document are maintenance free.
Cleaning The exterior of the 850 Series Temperature Switch can be cleaned using a soft, moistened cloth. Heavy soiling can be removed using a mild cleaning agent. The switch must not be opened for cleaning! Aggressive chemicals or hard scrubbing can damage the surface, particularly the display film. Disposal The packaging and used parts must be disposed of in accordance with the regulations of the country in which the device is installed.
Notes: _________________________________________________________ _________________________________________________________ _________________________________________________________ _________________________________________________________ _________________________________________________________ _________________________________________________________ _________________________________________________________ _________________________________________________________ _________________________________________