Installation Guide
Installation of the aerator and Bio-Kinetic system should take place when the Singulair Green system is ready for start-up.
Refer to the Bio-Kinetic System Installation instructions for additional details regarding the installation of the Bio-Kinetic
system. Your delivery truck driver should have instructed the contractor or owner to contact your office and make arrangements
for equipment installation to occur after the home is occupied and the sanitary sewer is in use. Review your Singulair Green
tank setting records weekly to insure that you do not have equipment installations that are overdue. If you suspect that
adequate time has passed for system start-up and you have not yet heard from the owners, contact them to schedule
equipment installation.
PRE-INSTALLATION CHECKLIST
The installer should have accurate directions to the facility and a list of service inspections due at other installations in
the vicinity.
The service vehicle should carry the Singulair Tool Kaddy fully stocked with tools, spare parts and test equipment for
use during installation.
The installer should have the Singulair Green Installation Manual.
Someone should be present at the location to allow installer access to the control center and electrical service panel.
The main electrical service panel wiring must be complete so the aerator may be started-up and tested.
All chambers of the Singulair Green tankage should be full to the flow line.
The installer must have the proper model aerator for the installation.
The serial number on the aerator must match the service and warranty record card.
AERATOR START-UP PROCEDURE
When you arrive on site, introduce yourself to the owner and
ask to see the main electrical service panel and Service Pro
control center. Be certain the circuit for the Singulair Green
system in the main electrical service panel is
de-energized and that the selector switch in the Service Pro
control center is placed in the “off” position.
Explain to the owner that you will be installing the aerator
into the aeration chamber of the tank and you will need
access to the main electrical service panel for system
start-up after the aerator has been installed. Carry the aerator
in its shipping carton to the tank site. Place the Singulair
Tool Kaddy nearby for easy access to tools and test
equipment. Remove the vented cover from the aerator
mounting riser. Carefully remove the aspirator shaft from
the shipping carton. Do not bump or bend the aspirator
shaft. Lay the shaft on the vented cover. Grip the outside
bottom of the shipping carton with your feet and lift the aerator
to remove it. Lay the aerator on its side with the brackets
resting on the vented cover near the aerator mounting riser.
Uncoil the underground electrical service cable from inside
the aerator mounting riser and extend it out of the riser.
Test the exposed leads with the electrical multi-meter from
the Tool Kaddy before proceeding. The circuit should not be
energized and voltage should not be evident when the leads
are tested with the multi-meter.
WIRING THE ELECTRICAL CONNECTOR
The moisture resistant electrical connector must be
properly wired to insure system operation and protect
components. Carefully follow these steps to completely
wire the electrical connector:
1. Uncouple the two halves of the electrical connector on
the Singulair aerator. Unscrew the three captive stainless
steel screws from the face of the female half of the
assembly. They will stay in the body of the receptacle.
Lift out the rigid internal receptacle body.
2. Unscrew the compression nut on the strain relief
connector assembly at the small end of the female half
of the connector. Do not misplace the compression
ring. Insert the electrical service cable through the
compression nut, compression ring and neoprene
grommet, which is contained in the molded plastic sleeve
of the female connector.
3. Strip the outer insulation back 1
1
/
4
" on the underground
electrical service cable and expose the three individual
leads. Use extreme care to be sure the insulation
jackets on the individual black and white leads are not
scarred or damaged while stripping the outer jacket.
Check them carefully. If even slight damage is noticed,
cut off the end of the cable just below your work and
begin again.
SINGULAIR GREEN
®
BIO-KINETIC
®
WASTEWATER TREATMENT SYSTEM
SINGULAIR
®
AERATOR INSTALLATION